Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Old Dominion Univ. |
---|---|
Assessment Year | 1998 |
Principal Product | Circuit Boards |
NAICS | n/a |
SIC | 2752 - Commercial Printing, Lithographic |
Sales | $1,000,000-$5,000,000 |
# of Employees | 34 |
Plant Area (Sq.Ft.) | 16,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 3,640 |
Location (State) | VA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $20,174 | 425,850 | kWh | $0.05 |
Electricity Demand | $10,923 | 1,976 | kW-months/year | $5.53 |
Electricity Fees | $5,722 | - | $ | - |
Natural Gas | $4,242 | 541 | MMBtu | $7.84 |
TOTAL ENERGY COSTS | $44,126 | |||
RECOMMENDED SAVINGS* | $5,182 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,196 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $2,986 Cost: $1,615 |
$3,737 | 78,839 | $1,191 | 360 | $(-1,942) | (-269) |
$3,737 78,839 kWh |
$1,191 360 kW-months/year |
$(-1,942) (-269) MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $925 Cost: $2,175 |
$636 | 13,482 | $289 | 52 | - | - |
$636 13,482 kWh |
$289 52 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $921 Cost: $800 |
$921 | 19,343 | - | - | - | - |
$921 19,343 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $95 Cost: $91 |
$62 | 1,172 | $33 | 6 | - | - |
$62 1,172 kWh |
$33 6 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $255 Cost: $255 |
$184 | 3,810 | $71 | 13 | - | - |
$184 3,810 kWh |
$71 13 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $5,182 Cost: $4,936 |
$5,540 | 116,646 | $1,584 | 431 | $(-1,942) | (-269) | $5,540 116,646 kWh |
$1,584 431 kW-months/year |
$(-1,942) (-269) MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,196 Cost: $3,321 |
$1,803 | 37,807 | $393 | 71 | - | - | $1,803 37,807 kWh |
$393 71 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |