Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Old Dominion Univ. |
---|---|
Assessment Year | 1998 |
Principal Product | Paper Moisture Barriers |
NAICS | n/a |
SIC | 2672 - Paper Coated And Laminated, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 105 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 8,760 |
Location (State) | VA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $61,337 | 3,848,769 | kWh | $0.02 |
Electricity Demand | $106,193 | 7,007 | kW-months/year | $15.16 |
Electricity Fees | $2,471 | - | $ | - |
Natural Gas | $72,643 | 11,895 | MMBtu | $6.11 |
TOTAL ENERGY COSTS | $242,644 | |||
RECOMMENDED SAVINGS* | $29,608 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $24,320 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Consumption | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Water Consumption | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $11,192 Cost: $6,908 |
$4,853 | 305,100 | $6,339 | 418 | - | - | - | - | - | - |
$4,853 305,100 kWh |
$6,339 418 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4113 INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS |
Savings: $3,843 Cost: $9,910 |
$1,402 | 88,218 | $2,441 | 161 | - | - | - | - | - | - |
$1,402 88,218 kWh |
$2,441 161 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $241 Cost: $420 |
$241 | 15,240 | - | - | - | - | - | - | - | - |
$241 15,240 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $365 Cost: $220 |
$365 | 22,860 | - | - | - | - | - | - | - | - |
$365 22,860 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $672 Cost: $110 |
- | - | - | - | $672 | 110 | - | - | - | - |
- - kWh |
- - kW-months/year |
$672 110 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $1,833 Cost: $1,495 |
- | - | - | - | $1,833 | 300 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,833 300 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2111 INSTALL STEAM TRAP |
Savings: $1,445 Cost: $560 |
- | - | - | - | $1,226 | 88 | $219 | - | - | - |
- - kWh |
- - kW-months/year |
$1,226 88 MMBtu |
$219 - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4156 ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM |
Savings: $10,017 Cost: $2,800 |
- | - | - | - | - | - | - | - | $10,017 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$10,017 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $29,608 Cost: $22,423 |
$6,861 | 431,418 | $8,780 | 579 | $3,731 | 498 | $219 | - | $10,017 | - | $6,861 431,418 kWh |
$8,780 579 kW-months/year |
$3,731 498 MMBtu |
$219 - Tgal |
$10,017 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $24,320 Cost: $11,953 |
$5,459 | 343,200 | $6,339 | 418 | $2,505 | 410 | - | - | $10,017 | - | $5,459 343,200 kWh |
$6,339 418 kW-months/year |
$2,505 410 MMBtu |
- - Tgal |
$10,017 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Consumption | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Water Consumption | Primary Product |