Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Old Dominion Univ. |
---|---|
Assessment Year | 1999 |
Principal Product | Cat Litter |
NAICS | n/a |
SIC | 3298 - |
Sales | $5,000,000-$10,000,000 |
# of Employees | 43 |
Plant Area (Sq.Ft.) | 60,043 |
Annual Production | 0 Units |
Production Hrs. Annual | 6,240 |
Location (State) | VA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $91,594 | 2,082,943 | kWh | $0.04 |
Electricity Demand | $44,436 | 5,646 | kW-months/year | $7.87 |
Electricity Fees | $(-1,667) | - | $ | - |
LPG | $9,096 | 932 | MMBtu | $9.76 |
Wood | $194,472 | 118,571 | MMBtu | $1.64 |
TOTAL ENERGY COSTS | $337,931 | |||
RECOMMENDED SAVINGS* | $104,453 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Wood | Primary Raw Material | Electricity Usage | Electricity Demand | Wood | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,888 Cost: $13,066 |
$1,008 | 22,860 | $880 | 112 | - | - | - | - |
$1,008 22,860 kWh |
$880 112 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,153 Cost: $800 |
$2,153 | 48,945 | - | - | - | - | - | - |
$2,153 48,945 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $8,350 Cost: $30,000 |
- | - | - | - | $8,350 | 9,050 | - | - |
- - kWh |
- - kW-months/year |
$8,350 9,050 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.131 MODIFY PROCESS TO REDUCE MATERIAL USE/COST |
Savings: $92,062 Cost: $180,000 |
- | - | - | - | - | - | $92,062 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$92,062 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $104,453 Cost: $223,866 |
$3,161 | 71,805 | $880 | 112 | $8,350 | 9,050 | $92,062 | - | $3,161 71,805 kWh |
$880 112 kW-months/year |
$8,350 9,050 MMBtu |
$92,062 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Wood | Primary Raw Material | Electricity Usage | Electricity Demand | Wood | Primary Raw Material |