Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Old Dominion Univ. |
---|---|
Assessment Year | 2000 |
Principal Product | Road Signs |
NAICS | n/a |
SIC | 3993 - Signs And Advertising Specialities |
Sales | $5,000,000-$10,000,000 |
# of Employees | 38 |
Plant Area (Sq.Ft.) | 27,000 |
Annual Production | 750,000 Thousand Feet |
Production Hrs. Annual | 4,004 |
Location (State) | VA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $25,826 | 465,709 | kWh | $0.06 |
Electricity Demand | $7,533 | 1,934 | kW-months/year | $3.90 |
Electricity Fees | $1,491 | - | $ | - |
Natural Gas | $8,563 | 1,054 | MMBtu | $8.12 |
TOTAL ENERGY COSTS | $44,195 | |||
RECOMMENDED SAVINGS* | $7,004 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $266 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,380 Cost: $3,814 |
$1,140 | 20,516 | $240 | 62 | - | - | - | - |
$1,140 20,516 kWh |
$240 62 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $884 Cost: $2,163 |
$826 | 12,309 | $58 | 15 | - | - | - | - |
$826 12,309 kWh |
$58 15 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $266 Cost: $200 |
$266 | 4,689 | - | - | - | - | - | - |
$266 4,689 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $158 Cost: $13 |
$99 | 1,758 | $21 | 5 | - | - | $38 | - |
$99 1,758 kWh |
$21 5 kW-months/year |
- - MMBtu |
$38 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $1,218 Cost: $150 |
- | - | - | - | $1,218 | 252 | - | - |
- - kWh |
- - kW-months/year |
$1,218 252 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $2,218 Cost: $135 |
$2,218 | 39,859 | - | - | - | - | - | - |
$2,218 39,859 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $70 Cost: - |
$70 | 1,172 | - | - | - | - | - | - |
$70 1,172 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $155 Cost: $20 |
$155 | 2,931 | - | - | - | - | - | - |
$155 2,931 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $655 Cost: $150 |
$115 | 2,052 | - | - | $540 | 112 | - | - |
$115 2,052 kWh |
- - kW-months/year |
$540 112 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $7,004 Cost: $6,645 |
$4,889 | 85,286 | $319 | 82 | $1,758 | 364 | $38 | - | $4,889 85,286 kWh |
$319 82 kW-months/year |
$1,758 364 MMBtu |
$38 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $266 Cost: $200 |
$266 | 4,689 | - | - | - | - | - | - | $266 4,689 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost |