Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Old Dominion Univ.
Assessment Year 2000
Principal Product processed food
NAICS n/a
SIC 2013 - Sausages And Other Prepared Meats
Sales $1,000,000-$5,000,000
# of Employees 16
Plant Area (Sq.Ft.) 9,000
Annual Production 0 Units
Production Hrs. Annual 2,340
Location (State) VA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $142,402 3,321,219 kWh $0.04
Electricity Fees $3,072 - $ -
Fuel Oil #4 $26,289 5,375 MMBtu $4.89
TOTAL ENERGY COSTS $171,763
RECOMMENDED SAVINGS* $2,959 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,184
Cost:
$2,257
$1,184 18,757 $1,184
18,757
kWh
02: 2.4113 INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS Savings:
$1,775
Cost:
$1,870
$1,775 30,188 $1,775
30,188
kWh
TOTAL RECOMMENDED Savings:
$2,959
Cost:
$4,127
$2,959 48,945 $2,959
48,945
kWh
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - -
-
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage