Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Old Dominion Univ. |
---|---|
Assessment Year | 2000 |
Principal Product | Yarn spinning mills |
NAICS | n/a |
SIC | 2281 - Yarn Spinning Mills |
Sales | $10,000,000-$50,000,000 |
# of Employees | 60 |
Plant Area (Sq.Ft.) | 139,627 |
Annual Production | 0 Units |
Production Hrs. Annual | 7,200 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $284,273 | 6,411,782 | kWh | $0.04 |
Electricity Demand | $148,909 | 14,013 | kW-months/year | $10.63 |
Electricity Fees | $15,965 | - | $ | - |
Fuel Oil #4 | $138,408 | 36,299 | MMBtu | $3.81 |
TOTAL ENERGY COSTS | $587,555 | |||
RECOMMENDED SAVINGS* | $110,809 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $91,751 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #4 | Electricity Usage | Electricity Demand | Fuel Oil #4 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $89,664 Cost: $154,663 |
$63,695 | 1,438,159 | $25,969 | 2,443 | - | - |
$63,695 1,438,159 kWh |
$25,969 2,443 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $19,058 Cost: $2,100 |
- | - | - | - | $19,058 | 5,042 |
- - kWh |
- - kW-months/year |
$19,058 5,042 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,087 Cost: $1,800 |
$1,492 | 33,705 | $595 | 56 | - | - |
$1,492 33,705 kWh |
$595 56 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $110,809 Cost: $158,563 |
$65,187 | 1,471,864 | $26,564 | 2,499 | $19,058 | 5,042 | $65,187 1,471,864 kWh |
$26,564 2,499 kW-months/year |
$19,058 5,042 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $91,751 Cost: $156,463 |
$65,187 | 1,471,864 | $26,564 | 2,499 | - | - | $65,187 1,471,864 kWh |
$26,564 2,499 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #4 | Electricity Usage | Electricity Demand | Fuel Oil #4 |