IAC Center Oklahoma State University
Assessment Year 1982
Principal Product HEAT EXCHANGERS
NAICS -
SIC 3443 - Fabricated Plate Work (boiler Shops)
Sales $7,200,000
# of Employees 125
Plant Area (Sq.Ft.) 0
Annual Production 7,800,000 Pounds
Production Hrs. Annual 4,250
Location (State) OK
Source Yearly Cost Usage
Electricity Usage $48,904 885,991
Natural Gas $7,511 2,907
TOTAL ENERGY COSTS $56,415
RECOMMENDED SAVINGS* $19,356 *Non-energy impacts
included in savings.
IMPLEMENTED SAVINGS* -
#|Description Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$8,321
Cost:
$24,185
$8,321 286,928 - - $8,321
286,928
kWh
-
-
MMBtu
02: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$4,332
Cost:
$15,000
$4,332 - - - $4,332
-
kWh
-
-
MMBtu
03: 2.7143 USE MORE EFFICIENT LIGHT SOURCE Savings:
$4,256
Cost:
$13,760
$4,256 92,614 - - $4,256
92,614
kWh
-
-
MMBtu
04: 2.7143 USE MORE EFFICIENT LIGHT SOURCE Savings:
$2,141
Cost:
$6,006
$2,141 73,857 - - $2,141
73,857
kWh
-
-
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$156
Cost:
$78
$156 2,638 - - $156
2,638
kWh
-
-
MMBtu
06: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$150
Cost:
$75
- - $150 58 -
-
kWh
$150
58
MMBtu
TOTAL RECOMMENDED Savings:
$19,356
Cost:
$59,104
$19,206 456,037 $150 58 $19,206
456,037
kWh
$150
58
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas
Back to Top