IAC logo
IAC Assessment: OK0054
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: OK0054
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 1982
Principal Product PLASTIC CONTAINERS
NAICS n/a
SIC 3089 - Plastics Products, Nec
Sales $10,000,000-$50,000,000
# of Employees 90
Plant Area (Sq.Ft.) 0
Annual Production 0 Units
Production Hrs. Annual 6,000
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $154,700 4,149,473 kWh $0.04
Natural Gas $17,005 5,515 MMBtu $3.08
TOTAL ENERGY COSTS $171,705
RECOMMENDED SAVINGS* $37,358 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$6,115
Cost:
$140
$6,115 213,365 - - $6,115
213,365
kWh
-
-
MMBtu
02: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$5,398
Cost:
$100
$3,218 112,251 $2,180 754 $3,218
112,251
kWh
$2,180
754
MMBtu
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$644
Cost:
$100
- - $644 156 -
-
kWh
$644
156
MMBtu
04: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$4,457
Cost:
-
- - $4,457 1,080 -
-
kWh
$4,457
1,080
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,550
Cost:
$7,500
$3,550 106,389 - - $3,550
106,389
kWh
-
-
MMBtu
06: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT Savings:
$258
Cost:
-
$258 5,862 - - $258
5,862
kWh
-
-
MMBtu
07: 2.7494 INSTALL STORM WINDOWS AND DOORS Savings:
$449
Cost:
$572
$193 6,741 $256 88 $193
6,741
kWh
$256
88
MMBtu
08: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$13,226
Cost:
$17,775
$13,226 395,369 - - $13,226
395,369
kWh
-
-
MMBtu
09: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE Savings:
$3,261
Cost:
$4,000
$3,261 113,716 - - $3,261
113,716
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$37,358
Cost:
$30,187
$29,821 953,693 $7,537 2,078 $29,821
953,693
kWh
$7,537
2,078
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas