Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 1984
Principal Product HEAT EXCHANGERS
NAICS n/a
SIC 3443 - Fabricated Plate Work (boiler Shops)
Sales $1,000,000-$5,000,000
# of Employees 45
Plant Area (Sq.Ft.) 0
Annual Production 600 Pieces
Production Hrs. Annual 2,080
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $40,256 701,641 kWh $0.06
Natural Gas $16,329 4,314 MMBtu $3.79
TOTAL ENERGY COSTS $56,585
RECOMMENDED SAVINGS* $7,663 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $7,663
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$5,465
Cost:
$650
- - $5,465 1,423 -
-
kWh
$5,465
1,423
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$130
Cost:
$30
$130 2,052 - - $130
2,052
kWh
-
-
MMBtu
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,730
Cost:
$256
$1,730 28,722 - - $1,730
28,722
kWh
-
-
MMBtu
04: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$56
Cost:
-
$56 879 - - $56
879
kWh
-
-
MMBtu
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$218
Cost:
$516
- - $218 57 -
-
kWh
$218
57
MMBtu
06: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$64
Cost:
$485
$64 1,172 - - $64
1,172
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$7,663
Cost:
$1,937
$1,980 32,825 $5,683 1,480 $1,980
32,825
kWh
$5,683
1,480
MMBtu
TOTAL IMPLEMENTED Savings:
$7,663
Cost:
$1,937
$1,980 32,825 $5,683 1,480 $1,980
32,825
kWh
$5,683
1,480
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas