IAC logo
IAC Assessment: OK0163
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: OK0163
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 1985
Principal Product REFINING GASKETS
NAICS n/a
SIC 3053 - Gaskets, Packing And Sealing Devices
Sales $1,000,000-$5,000,000
# of Employees 35
Plant Area (Sq.Ft.) 0
Annual Production 0 Units
Production Hrs. Annual 0
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $13,513 219,226 kWh $0.06
Natural Gas $3,409 686 MMBtu $4.97
TOTAL ENERGY COSTS $16,922
RECOMMENDED SAVINGS* $1,679 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $1,652
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$257
Cost:
$360
- - $257 57 -
-
kWh
$257
57
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$80
Cost:
$138
$80 1,465 - - $80
1,465
kWh
-
-
MMBtu
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$720
Cost:
$200
$720 13,775 - - $720
13,775
kWh
-
-
MMBtu
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$61
Cost:
-
$61 1,172 - - $61
1,172
kWh
-
-
MMBtu
05: 2.6121 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED Savings:
$110
Cost:
-
$110 2,052 - - $110
2,052
kWh
-
-
MMBtu
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$258
Cost:
$139
$258 4,982 - - $258
4,982
kWh
-
-
MMBtu
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$83
Cost:
$78
$83 1,465 - - $83
1,465
kWh
-
-
MMBtu
08: 2.6232 INSTALL SET-BACK TIMERS Savings:
$83
Cost:
$45
$83 1,465 - - $83
1,465
kWh
-
-
MMBtu
09: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$27
Cost:
$190
$27 586 - - $27
586
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$1,679
Cost:
$1,150
$1,422 26,962 $257 57 $1,422
26,962
kWh
$257
57
MMBtu
TOTAL IMPLEMENTED Savings:
$1,652
Cost:
$960
$1,395 26,376 $257 57 $1,395
26,376
kWh
$257
57
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas