Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 1988
Principal Product PIPE FITTINGS
NAICS n/a
SIC 3494 - Valves And Pipe Fittings, Nec
Sales $5,000,000-$10,000,000
# of Employees 50
Plant Area (Sq.Ft.) 0
Annual Production 84,246 Pieces
Production Hrs. Annual 2,500
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $44,289 696,073 kWh $0.06
Natural Gas $12,362 3,009 MMBtu $4.11
TOTAL ENERGY COSTS $56,651
RECOMMENDED SAVINGS* $4,562 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $3,673
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$301
Cost:
$159
$301 4,689 - - - - $301
4,689
kWh
-
-
MMBtu
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$122
Cost:
$255
$122 1,758 - - - - $122
1,758
kWh
-
-
MMBtu
-
-
$
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$302
Cost:
$420
- - $302 74 - - -
-
kWh
$302
74
MMBtu
-
-
$
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$435
Cost:
-
$545 14,947 - - $(-110) - $545
14,947
kWh
-
-
MMBtu
$(-110)
-
$
05: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$1,766
Cost:
$1,040
- - $1,766 430 - - -
-
kWh
$1,766
430
MMBtu
-
-
$
06: 2.6232 INSTALL SET-BACK TIMERS Savings:
$415
Cost:
$115
$415 6,155 - - - - $415
6,155
kWh
-
-
MMBtu
-
-
$
07: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$172
Cost:
$20
$172 2,638 - - - - $172
2,638
kWh
-
-
MMBtu
-
-
$
08: 2.7228 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM Savings:
$717
Cost:
$380
$717 10,551 - - - - $717
10,551
kWh
-
-
MMBtu
-
-
$
09: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$332
Cost:
$275
$332 9,086 - - - - $332
9,086
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$4,562
Cost:
$2,664
$2,604 49,824 $2,068 504 $(-110) - $2,604
49,824
kWh
$2,068
504
MMBtu
$(-110)
-
$
TOTAL IMPLEMENTED Savings:
$3,673
Cost:
$2,264
$1,715 36,635 $2,068 504 $(-110) - $1,715
36,635
kWh
$2,068
504
MMBtu
$(-110)
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes