Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 1992
Principal Product SUCKER RODS
NAICS n/a
SIC 3533 - Oil And Gas Field Machinery
Sales $10,000,000-$50,000,000
# of Employees 140
Plant Area (Sq.Ft.) 0
Annual Production 290,000 Pieces
Production Hrs. Annual 2,750
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $149,070 2,154,455 kWh $0.07
Natural Gas $99,477 36,882 MMBtu $2.70
TOTAL ENERGY COSTS $248,547
RECOMMENDED SAVINGS* $29,858 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $29,651
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.2426 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR Savings:
$17,190
Cost:
$35,000
- - $17,190 5,217 - - -
-
kWh
$17,190
5,217
MMBtu
-
-
$
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$8,318
Cost:
-
$8,538 142,145 - - $(-220) - $8,538
142,145
kWh
-
-
MMBtu
$(-220)
-
$
03: 2.7123 KEEP LAMPS AND REFLECTORS CLEAN Savings:
$2,549
Cost:
$11,123
$2,549 39,566 - - - - $2,549
39,566
kWh
-
-
MMBtu
-
-
$
04: 2.7123 KEEP LAMPS AND REFLECTORS CLEAN Savings:
$327
Cost:
$1,881
$327 4,982 - - - - $327
4,982
kWh
-
-
MMBtu
-
-
$
05: 2.6232 INSTALL SET-BACK TIMERS Savings:
$207
Cost:
$372
$207 3,517 - - - - $207
3,517
kWh
-
-
MMBtu
-
-
$
06: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$758
Cost:
$816
- - $758 230 - - -
-
kWh
$758
230
MMBtu
-
-
$
07: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$509
Cost:
$4,350
$509 7,913 - - - - $509
7,913
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$29,858
Cost:
$53,542
$12,130 198,123 $17,948 5,447 $(-220) - $12,130
198,123
kWh
$17,948
5,447
MMBtu
$(-220)
-
$
TOTAL IMPLEMENTED Savings:
$29,651
Cost:
$53,170
$11,923 194,606 $17,948 5,447 $(-220) - $11,923
194,606
kWh
$17,948
5,447
MMBtu
$(-220)
-
$
Savings
Cost
$ kWh $ MMBtu $ $