IAC logo
IAC Assessment: OK0389
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: OK0389
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 1992
Principal Product STRUCTURAL STEEL
NAICS n/a
SIC 3441 - Fabricated Structural Metal
Sales $10,000,000-$50,000,000
# of Employees 90
Plant Area (Sq.Ft.) 0
Annual Production 65,000 Tons
Production Hrs. Annual 6,864
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $65,834 966,589 kWh $0.07
Natural Gas $18,812 3,862 MMBtu $4.87
TOTAL ENERGY COSTS $84,646
RECOMMENDED SAVINGS* $8,246 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $4,724
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,084
Cost:
$200
$2,284 64,771 - - $(-200) - $2,284
64,771
kWh
-
-
MMBtu
$(-200)
-
$
02: 2.7123 KEEP LAMPS AND REFLECTORS CLEAN Savings:
$2,686
Cost:
$6,210
$2,723 39,566 $(-280) (-74) $243 - $2,723
39,566
kWh
$(-280)
(-74)
MMBtu
$243
-
$
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$1,437
Cost:
$1,350
$1,437 28,722 - - - - $1,437
28,722
kWh
-
-
MMBtu
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$941
Cost:
$1,348
$576 8,499 - - $365 - $576
8,499
kWh
-
-
MMBtu
$365
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$262
Cost:
$1,385
$469 3,810 $(-27) (-7) $(-180) - $469
3,810
kWh
$(-27)
(-7)
MMBtu
$(-180)
-
$
06: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$371
Cost:
$203
- - $371 98 - - -
-
kWh
$371
98
MMBtu
-
-
$
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$201
Cost:
$683
$201 5,569 - - - - $201
5,569
kWh
-
-
MMBtu
-
-
$
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$264
Cost:
$147
$264 2,345 - - - - $264
2,345
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$8,246
Cost:
$11,526
$7,954 153,282 $64 17 $228 - $7,954
153,282
kWh
$64
17
MMBtu
$228
-
$
TOTAL IMPLEMENTED Savings:
$4,724
Cost:
$4,283
$4,766 105,802 $(-27) (-7) $(-15) - $4,766
105,802
kWh
$(-27)
(-7)
MMBtu
$(-15)
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes