IAC logo
IAC Assessment: OK0419
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: OK0419
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 1993
Principal Product Polypropylene & Polyethylene Product
NAICS n/a
SIC 3089 - Plastics Products, Nec
Sales $1,000,000-$5,000,000
# of Employees 150
Plant Area (Sq.Ft.) 95,200
Annual Production 5,640,000 Pounds
Production Hrs. Annual 8,352
Location (State) KS
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $474,500 9,764,068 kWh $0.05
Natural Gas $3,831 1,087 MMBtu $3.52
TOTAL ENERGY COSTS $478,331
RECOMMENDED SAVINGS* $31,411 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $2,613
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$17,780
Cost:
$23,320
$17,780 334,408 $17,780
334,408
kWh
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,934
Cost:
$15,211
$5,934 112,837 $5,934
112,837
kWh
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,338
Cost:
-
$2,338 47,479 $2,338
47,479
kWh
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$2,331
Cost:
$6,008
$2,331 46,307 $2,331
46,307
kWh
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,053
Cost:
$3,174
$2,053 36,635 $2,053
36,635
kWh
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$700
Cost:
-
$700 13,775 $700
13,775
kWh
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$275
Cost:
$432
$275 5,569 $275
5,569
kWh
TOTAL RECOMMENDED Savings:
$31,411
Cost:
$48,145
$31,411 597,010 $31,411
597,010
kWh
TOTAL IMPLEMENTED Savings:
$2,613
Cost:
$432
$2,613 53,048 $2,613
53,048
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage