Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 1994
Principal Product Fabric covers
NAICS n/a
SIC 2394 - Canvas And Related Products
Sales $10,000,000-$50,000,000
# of Employees 220
Plant Area (Sq.Ft.) 110,000
Annual Production 100,000 Pieces
Production Hrs. Annual 7,280
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $138,371 1,775,791 kWh $0.08
Natural Gas $11,668 2,384 MMBtu $4.89
TOTAL ENERGY COSTS $150,039
RECOMMENDED SAVINGS* $7,952 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $2,091
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,087
Cost:
$6,264
$2,087 31,067 - - $2,087
31,067
kWh
-
-
MMBtu
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$2,150
Cost:
$6,790
$2,943 48,945 $(-793) (-192) $2,943
48,945
kWh
$(-793)
(-192)
MMBtu
03: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$1,624
Cost:
$4,901
$1,624 64,478 - - $1,624
64,478
kWh
-
-
MMBtu
04: 2.7131 ADD AREA LIGHTING SWITCHES Savings:
$861
Cost:
$1,272
$861 33,998 - - $861
33,998
kWh
-
-
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$513
Cost:
$997
$513 3,810 - - $513
3,810
kWh
-
-
MMBtu
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$419
Cost:
$544
- - $419 101 -
-
kWh
$419
101
MMBtu
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$298
Cost:
$655
$298 6,155 - - $298
6,155
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$7,952
Cost:
$21,423
$8,326 188,453 $(-374) (-91) $8,326
188,453
kWh
$(-374)
(-91)
MMBtu
TOTAL IMPLEMENTED Savings:
$2,091
Cost:
$3,468
$1,672 43,963 $419 101 $1,672
43,963
kWh
$419
101
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas