Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 1995 |
Principal Product | Air conditioning equipment |
NAICS | n/a |
SIC | 3585 - Refrigeration And Heating Equipment |
Sales | $10,000,000-$50,000,000 |
# of Employees | 205 |
Plant Area (Sq.Ft.) | 117,500 |
Annual Production | 800 Pieces |
Production Hrs. Annual | 4,576 |
Location (State) | OK |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $117,507 | 1,722,450 | kWh | $0.07 |
Natural Gas | $41,466 | 10,019 | MMBtu | $4.14 |
TOTAL ENERGY COSTS | $158,973 | |||
RECOMMENDED SAVINGS* | $55,067 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $48,621 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Other Liquid (non-haz) | Administrative Changes | Electricity Usage | Natural Gas | Other Liquid (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | gal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $37,301 Cost: $2,000 |
- | - | - | - | - | - | $37,301 | - |
- - kWh |
- - MMBtu |
- - gal |
$37,301 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.7224 USE PUMPS AND PIPING TO DECREASE THE FREQUENCY OF SPILLAGE DURING MATERIAL TRANSFER |
Savings: $3,872 Cost: $7,422 |
- | - | - | - | $3,872 | 1,238 | - | - |
- - kWh |
- - MMBtu |
$3,872 1,238 gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.8142 DISTILL CONTAMINATED SOLVENTS FOR REUSE |
Savings: $6,347 Cost: $6,240 |
- | - | - | - | $6,347 | 990 | - | - |
- - kWh |
- - MMBtu |
$6,347 990 gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,609 Cost: $170 |
$2,609 | 50,410 | - | - | - | - | - | - |
$2,609 50,410 kWh |
- - MMBtu |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $4,193 Cost: $1,736 |
- | - | $4,193 | 1,013 | - | - | - | - |
- - kWh |
$4,193 1,013 MMBtu |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $379 Cost: $300 |
$379 | 7,620 | - | - | - | - | - | - |
$379 7,620 kWh |
- - MMBtu |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $267 Cost: $791 |
$267 | 4,982 | - | - | - | - | - | - |
$267 4,982 kWh |
- - MMBtu |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $99 Cost: $240 |
$99 | 1,172 | - | - | - | - | - | - |
$99 1,172 kWh |
- - MMBtu |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $55,067 Cost: $18,899 |
$3,354 | 64,184 | $4,193 | 1,013 | $10,219 | 2,228 | $37,301 | - | $3,354 64,184 kWh |
$4,193 1,013 MMBtu |
$10,219 2,228 gal |
$37,301 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $48,621 Cost: $12,419 |
$3,255 | 63,012 | $4,193 | 1,013 | $3,872 | 1,238 | $37,301 | - | $3,255 63,012 kWh |
$4,193 1,013 MMBtu |
$3,872 1,238 gal |
$37,301 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | gal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Other Liquid (non-haz) | Administrative Changes | Electricity Usage | Natural Gas | Other Liquid (non-haz) | Administrative Changes |