Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 1997 |
Principal Product | Custom-made Motor Coaches |
NAICS | n/a |
SIC | 3711 - Motor Vehicles And Car Bodies |
Sales | $10,000,000-$50,000,000 |
# of Employees | 140 |
Plant Area (Sq.Ft.) | 200,000 |
Annual Production | 36 Pieces |
Production Hrs. Annual | 2,600 |
Location (State) | OK |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $30,367 | 815,944 | kWh | $0.04 |
Electricity Demand | $15,886 | 3,229 | kW-months/year | $4.92 |
Natural Gas | $33,903 | 8,250 | MMBtu | $4.11 |
TOTAL ENERGY COSTS | $89,366 | |||
RECOMMENDED SAVINGS* | $59,442 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $4,736 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | gal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.311 SCHEDULE DELIVERIES ACCORDING TO DEMAND |
Savings: $37,800 Cost: $20,000 |
- | - | - | - | - | - | - | - | - | - | - | - | $37,800 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - gal |
- - lb |
$37,800 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $7,974 Cost: $7,000 |
- | - | - | - | $7,974 | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$7,974 - $ |
- - MMBtu |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.3125 USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS |
Savings: $6,792 Cost: $22,365 |
- | - | - | - | - | - | - | - | $6,792 | 11,440 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$6,792 11,440 gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,030 Cost: $4,595 |
$3,230 | 98,769 | $800 | 175 | - | - | - | - | - | - | - | - | - | - |
$3,230 98,769 kWh |
$800 175 kW-months/year |
- - $ |
- - MMBtu |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7314 REDUCE VENTILATION AIR |
Savings: $1,370 Cost: $5,600 |
$1,370 | 41,911 | - | - | - | - | - | - | - | - | - | - | - | - |
$1,370 41,911 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5248 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE |
Savings: $770 Cost: - |
- | - | - | - | - | - | - | - | - | - | $770 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - gal |
$770 - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $499 Cost: $1,086 |
- | - | - | - | - | - | $499 | 121 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$499 121 MMBtu |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $207 Cost: $1,440 |
$174 | 5,275 | $33 | 7 | - | - | - | - | - | - | - | - | - | - |
$174 5,275 kWh |
$33 7 kW-months/year |
- - $ |
- - MMBtu |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $59,442 Cost: $62,086 |
$4,774 | 145,955 | $833 | 182 | $7,974 | - | $499 | 121 | $6,792 | 11,440 | $770 | - | $37,800 | - | $4,774 145,955 kWh |
$833 182 kW-months/year |
$7,974 - $ |
$499 121 MMBtu |
$6,792 11,440 gal |
$770 - lb |
$37,800 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $4,736 Cost: $7,121 |
$3,404 | 104,044 | $833 | 182 | - | - | $499 | 121 | - | - | - | - | - | - | $3,404 104,044 kWh |
$833 182 kW-months/year |
- - $ |
$499 121 MMBtu |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | gal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | Administrative Changes |