IAC logo
IAC Assessment: OK0589
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: OK0589
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 2000
Principal Product Steel Pipe
NAICS n/a
SIC 3317 - Steel Pipe And Tubes
Sales $5,000,000-$10,000,000
# of Employees 45
Plant Area (Sq.Ft.) 23,000
Annual Production 5,000 Units
Production Hrs. Annual 6,240
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $62,173 1,697,831 kWh $0.04
Electricity Demand $66,880 - kW-months/year -
Electricity Fees $384 - $ -
Natural Gas $46,920 19,610 MMBtu $2.39
TOTAL ENERGY COSTS $177,817
RECOMMENDED SAVINGS* $102,733 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $102,733
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Solid Waste (non-haz) Personnel Changes Electricity Usage Electricity Demand Solid Waste (non-haz) Personnel Changes
$ kWh $ kW-months/year $ lb $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$7,862
Cost:
$1,900
$2,848 136,870 $5,014 264 - - - - $2,848
136,870
kWh
$5,014
264
kW-months/year
-
-
lb
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,093
Cost:
$4,942
$1,336 36,635 $757 70 - - - - $1,336
36,635
kWh
$757
70
kW-months/year
-
-
lb
-
-
$
03: 2.7134 USE PHOTOCELL CONTROLS Savings:
$504
Cost:
$136
$240 6,448 $264 24 - - - - $240
6,448
kWh
$264
24
kW-months/year
-
-
lb
-
-
$
04: 4.6520 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES Savings:
$72,000
Cost:
$230,000
- - - - - - $72,000 - -
-
kWh
-
-
kW-months/year
-
-
lb
$72,000
-
$
05: 3.5311 RECOVER AND REUSE WASTE MATERIAL Savings:
$20,274
Cost:
$59,400
- - - - $20,274 - - - -
-
kWh
-
-
kW-months/year
$20,274
-
lb
-
-
$
TOTAL RECOMMENDED Savings:
$102,733
Cost:
$296,378
$4,424 179,953 $6,035 358 $20,274 - $72,000 - $4,424
179,953
kWh
$6,035
358
kW-months/year
$20,274
-
lb
$72,000
-
$
TOTAL IMPLEMENTED Savings:
$102,733
Cost:
$296,378
$4,424 179,953 $6,035 358 $20,274 - $72,000 - $4,424
179,953
kWh
$6,035
358
kW-months/year
$20,274
-
lb
$72,000
-
$
Savings
Cost
$ kWh $ kW-months/year $ lb $ $
Electricity Usage Electricity Demand Solid Waste (non-haz) Personnel Changes Electricity Usage Electricity Demand Solid Waste (non-haz) Personnel Changes