Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2000 |
Principal Product | Metal Cutting Band Saw |
NAICS | n/a |
SIC | 3541 - Machine Tools, Metal Cutting Types |
Sales | $5,000,000-$10,000,000 |
# of Employees | 310 |
Plant Area (Sq.Ft.) | 140,000 |
Annual Production | 720 Pieces |
Production Hrs. Annual | 6,552 |
Location (State) | OK |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $42,145 | 2,351,700 | kWh | $0.02 |
Electricity Demand | $58,501 | - | kW-months/year | - |
Natural Gas | $20,966 | 5,039 | MMBtu | $4.16 |
TOTAL ENERGY COSTS | $114,452 | |||
RECOMMENDED SAVINGS* | $263,910 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $24,870 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $9,935 Cost: $800 |
$9,364 | 520,223 | $571 | 713 | - | - | - | - | - | - |
$9,364 520,223 kWh |
$571 713 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $8,177 Cost: $13,490 |
- | - | - | - | $8,177 | 585 | - | - | - | - |
- - kWh |
- - kW-months/year |
$8,177 585 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7145 INSTALL SKYLIGHTS |
Savings: $3,419 Cost: $2,000 |
$1,041 | 57,737 | $2,378 | 247 | - | - | - | - | - | - |
$1,041 57,737 kWh |
$2,378 247 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.446 AUTOMATE FINISHING PROCESS |
Savings: $137,280 Cost: $200,000 |
- | - | - | - | - | - | - | - | $137,280 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$137,280 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,339 Cost: $860 |
$2,098 | 33,705 | $2,053 | 213 | $(-812) | (-283) | - | - | - | - |
$2,098 33,705 kWh |
$2,053 213 kW-months/year |
$(-812) (-283) MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $1,028 Cost: - |
- | - | - | - | - | - | $1,028 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,028 - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7141 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS |
Savings: $81,900 Cost: $11,250 |
- | - | - | - | - | - | - | - | $81,900 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$81,900 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $10,512 Cost: $561 |
$5,556 | 235,346 | $4,956 | 368 | - | - | - | - | - | - |
$5,556 235,346 kWh |
$4,956 368 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.425 ELIMINATE/REDUCE REDUNDANT INSPECTIONS |
Savings: $8,320 Cost: - |
- | - | - | - | - | - | - | - | $8,320 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$8,320 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $263,910 Cost: $228,961 |
$18,059 | 847,011 | $9,958 | 1,541 | $7,365 | 302 | $1,028 | - | $227,500 | - | $18,059 847,011 kWh |
$9,958 1,541 kW-months/year |
$7,365 302 MMBtu |
$1,028 - lb |
$227,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $24,870 Cost: $17,150 |
$12,503 | 611,665 | $5,002 | 1,173 | $7,365 | 302 | - | - | - | - | $12,503 611,665 kWh |
$5,002 1,173 kW-months/year |
$7,365 302 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes |