Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2000 |
Principal Product | Brass Pipe Fittings |
NAICS | n/a |
SIC | 3494 - Valves And Pipe Fittings, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 400 |
Plant Area (Sq.Ft.) | 115,000 |
Annual Production | 18,940,541 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | OK |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $182,668 | 7,080,598 | kWh | $0.03 |
Electricity Demand | $98,433 | - | kW-months/year | - |
Electricity Fees | $6,470 | - | $ | - |
Natural Gas | $20,657 | 5,796 | MMBtu | $3.56 |
TOTAL ENERGY COSTS | $(-5,891,772) | |||
RECOMMENDED SAVINGS* | $663,292 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $397,327 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $621 Cost: $1,212 |
$468 | 18,171 | $153 | 25 | - | - | - | - |
$468 18,171 kWh |
$153 25 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $520 Cost: $708 |
$189 | 7,327 | $59 | 10 | $272 | - | - | - |
$189 7,327 kWh |
$59 10 kW-months/year |
$272 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $19,857 Cost: $90,984 |
$10,134 | 361,958 | $8,603 | 1,392 | - | - | $1,120 | - |
$10,134 361,958 kWh |
$8,603 1,392 kW-months/year |
- - $ |
$1,120 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,695 Cost: $3,700 |
$4,695 | 121,336 | - | - | - | - | - | - |
$4,695 121,336 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $664 Cost: $2,106 |
$664 | 25,791 | - | - | - | - | - | - |
$664 25,791 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $4,855 Cost: $6,930 |
$4,855 | 188,159 | - | - | - | - | - | - |
$4,855 188,159 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.2176 INCREASE USE OF AUTOMATION |
Savings: $367,920 Cost: $150,000 |
- | - | - | - | $367,920 | - | - | - |
- - kWh |
- - kW-months/year |
$367,920 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.446 AUTOMATE FINISHING PROCESS |
Savings: $227,760 Cost: $30,000 |
- | - | - | - | $227,760 | - | - | - |
- - kWh |
- - kW-months/year |
$227,760 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.711 INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM |
Savings: $36,400 Cost: $65,450 |
- | - | - | - | - | - | $36,400 | - |
- - kWh |
- - kW-months/year |
- - $ |
$36,400 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $663,292 Cost: $351,090 |
$21,005 | 722,742 | $8,815 | 1,427 | $595,952 | - | $37,520 | - | $21,005 722,742 kWh |
$8,815 1,427 kW-months/year |
$595,952 - $ |
$37,520 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $397,327 Cost: $251,614 |
$19,684 | 671,453 | $8,603 | 1,392 | $367,920 | - | $1,120 | - | $19,684 671,453 kWh |
$8,603 1,392 kW-months/year |
$367,920 - $ |
$1,120 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost |