Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2001 |
Principal Product | Aircraft Engine Internal Component Repair |
NAICS | n/a |
SIC | 3724 - Aircraft Engines And Engine Parts |
Sales | $10,000,000-$50,000,000 |
# of Employees | 235 |
Plant Area (Sq.Ft.) | 65,000 |
Annual Production | 150,000 Pieces |
Production Hrs. Annual | 8,760 |
Location (State) | OK |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $209,624 | 8,487,400 | kWh | $0.02 |
Electricity Demand | $216,758 | 37,160 | kW-months/year | $5.83 |
Electricity Fees | $240 | - | $ | - |
Natural Gas | $39,583 | 8,077 | MMBtu | $4.90 |
TOTAL ENERGY COSTS | $472,425 | |||
RECOMMENDED SAVINGS* | $20,094 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $11,794 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $147 Cost: $126 |
- | - | - | - | $147 | 30 | - | - |
- - kWh |
- - kW-months/year |
$147 30 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,500 Cost: $360 |
$3,500 | 141,828 | - | - | - | - | - | - |
$3,500 141,828 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $7,000 Cost: $13,300 |
$5,550 | 225,304 | $1,450 | 143 | - | - | - | - |
$5,550 225,304 kWh |
$1,450 143 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.426 MODIFY WORKLOAD |
Savings: $147 Cost: $70 |
$55 | 2,246 | $36 | 4 | - | - | $56 | - |
$55 2,246 kWh |
$36 4 kW-months/year |
- - MMBtu |
$56 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE |
Savings: $2,100 Cost: $5,800 |
- | - | $2,100 | 360 | - | - | - | - |
- - kWh |
$2,100 360 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7131 ADD AREA LIGHTING SWITCHES |
Savings: $1,000 Cost: $290 |
$1,000 | 35,040 | - | - | - | - | - | - |
$1,000 35,040 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $6,200 Cost: $5,734 |
$1,100 | 50,600 | - | - | $5,100 | 1,038 | - | - |
$1,100 50,600 kWh |
- - kW-months/year |
$5,100 1,038 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $20,094 Cost: $25,680 |
$11,205 | 455,018 | $3,586 | 507 | $5,247 | 1,068 | $56 | - | $11,205 455,018 kWh |
$3,586 507 kW-months/year |
$5,247 1,068 MMBtu |
$56 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $11,794 Cost: $14,146 |
$10,105 | 404,418 | $1,486 | 147 | $147 | 30 | $56 | - | $10,105 404,418 kWh |
$1,486 147 kW-months/year |
$147 30 MMBtu |
$56 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |