Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2001 |
Principal Product | Water Proofing Membrane |
NAICS | n/a |
SIC | 2851 - Paints And Allied Products |
Sales | $10,000,000-$50,000,000 |
# of Employees | 35 |
Plant Area (Sq.Ft.) | 15,120 |
Annual Production | 30,000 Thousand Feet |
Production Hrs. Annual | 3,650 |
Location (State) | OK |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $63,011 | 1,682,082 | kWh | $0.04 |
Electricity Fees | $40,760 | - | $ | - |
Natural Gas | $25,865 | 10,336 | MMBtu | $2.50 |
TOTAL ENERGY COSTS | $153,136 | |||
RECOMMENDED SAVINGS* | $75,853 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,527 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6232 INSTALL SET-BACK TIMERS |
Savings: $10,756 Cost: $1,026 |
- | - | - | - | $10,756 | 1,769 | - | - | - | - |
- - kWh |
- - kW-months/year |
$10,756 1,769 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $2,071 Cost: $4,000 |
- | - | - | - | $2,071 | 388 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,071 388 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $456 Cost: $2,600 |
- | - | - | - | $456 | 75 | - | - | - | - |
- - kWh |
- - kW-months/year |
$456 75 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $2,475 Cost: $7,120 |
- | - | - | - | $2,475 | 407 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,475 407 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $3,508 Cost: $6,000 |
- | - | - | - | $3,508 | 577 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,508 577 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $54,883 Cost: $20,680 |
$18,883 | 503,550 | - | - | - | - | $36,000 | - | - | - |
$18,883 503,550 kWh |
- - kW-months/year |
- - MMBtu |
$36,000 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $1,400 Cost: $572 |
$1,400 | 36,635 | - | - | - | - | - | - | - | - |
$1,400 36,635 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $304 Cost: $125 |
$49 | 1,314 | $215 | 2 | - | - | $108 | - | $(-68) | - |
$49 1,314 kWh |
$215 2 kW-months/year |
- - MMBtu |
$108 - $ |
$(-68) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $75,853 Cost: $42,123 |
$20,332 | 541,499 | $215 | 2 | $19,266 | 3,216 | $36,108 | - | $(-68) | - | $20,332 541,499 kWh |
$215 2 kW-months/year |
$19,266 3,216 MMBtu |
$36,108 - $ |
$(-68) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,527 Cost: $6,600 |
- | - | - | - | $2,527 | 463 | - | - | - | - | - - kWh |
- - kW-months/year |
$2,527 463 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |