Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2001 |
Principal Product | Dry Pet Food |
NAICS | n/a |
SIC | 2047 - Dog And Cat Food |
Sales | $10,000,000-$50,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 146,000 Tons |
Production Hrs. Annual | 3,480 |
Location (State) | OK |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $724,124 | 10,757,600 | kWh | $0.07 |
Natural Gas | $858,665 | 132,189 | MMBtu | $6.50 |
TOTAL ENERGY COSTS | $1,582,789 | |||
RECOMMENDED SAVINGS* | $55,200 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $21,808 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,798 Cost: $913 |
$270 | 8,322 | $75 | 11 | - | - | $825 | - | $628 | - |
$270 8,322 kWh |
$75 11 kW-months/year |
- - MMBtu |
$825 - $ |
$628 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,895 Cost: $5,476 |
$1,480 | 45,552 | $415 | 62 | - | - | - | - | - | - |
$1,480 45,552 kWh |
$415 62 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,844 Cost: $585 |
$1,844 | 56,858 | - | - | - | - | - | - | - | - |
$1,844 56,858 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $3,788 Cost: $250 |
- | - | - | - | $3,788 | 855 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,788 855 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $1,147 Cost: $238 |
- | - | - | - | $1,147 | 259 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,147 259 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $1,998 Cost: $6,000 |
- | - | - | - | $1,998 | 451 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,998 451 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $536 Cost: $163 |
- | - | - | - | $536 | 121 | - | - | - | - |
- - kWh |
- - kW-months/year |
$536 121 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $20,688 Cost: $8,572 |
- | - | - | - | $20,688 | 2,172 | - | - | - | - |
- - kWh |
- - kW-months/year |
$20,688 2,172 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7225 CLOSE OUTDOOR AIR DAMPERS DURING WARM-UP / COOL-DOWN PERIODS |
Savings: $13,745 Cost: $240 |
$10,890 | 335,160 | $3,095 | 1,074 | - | - | $(-240) | - | - | - |
$10,890 335,160 kWh |
$3,095 1,074 kW-months/year |
- - MMBtu |
$(-240) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.1224 REPLACE BOILER |
Savings: $7,761 Cost: $22,000 |
- | - | - | - | $7,761 | 1,752 | - | - | - | - |
- - kWh |
- - kW-months/year |
$7,761 1,752 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $55,200 Cost: $44,437 |
$14,484 | 445,892 | $3,585 | 1,147 | $35,918 | 5,610 | $585 | - | $628 | - | $14,484 445,892 kWh |
$3,585 1,147 kW-months/year |
$35,918 5,610 MMBtu |
$585 - $ |
$628 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $21,808 Cost: $6,714 |
$14,214 | 437,570 | $3,510 | 1,136 | $4,324 | 976 | $(-240) | - | - | - | $14,214 437,570 kWh |
$3,510 1,136 kW-months/year |
$4,324 976 MMBtu |
$(-240) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |