Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2001 |
Principal Product | Aluminum Foil |
NAICS | n/a |
SIC | 3353 - Aluminum Sheet, Plate, And Foil |
Sales | $50,000,000-$100,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 275,000 |
Annual Production | 3,750 Pieces |
Production Hrs. Annual | 8,760 |
Location (State) | AR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $333,544 | 40,869,000 | kWh | $0.01 |
Electricity Demand | $696,105 | 275,000 | kW-months/year | $2.53 |
Electricity Fees | $196,555 | - | $ | - |
Natural Gas | $3,623,445 | 864,066 | MMBtu | $4.19 |
TOTAL ENERGY COSTS | $5,377,498 | |||
RECOMMENDED SAVINGS* | $2,667,711 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $558,957 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $447 Cost: $2,790 |
$129 | 15,800 | $318 | 91 | - | - | - | - |
$129 15,800 kWh |
$318 91 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE |
Savings: $1,570 Cost: $1,040 |
$733 | 89,352 | $837 | 245 | - | - | - | - |
$733 89,352 kWh |
$837 245 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $17,387 Cost: $4,428 |
$721 | 87,900 | - | - | $16,666 | 3,974 | - | - |
$721 87,900 kWh |
- - kW-months/year |
$16,666 3,974 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4225 INSTALL COMMON HEADER ON COMPRESSORS |
Savings: $11,108 Cost: $7,010 |
$6,698 | 816,870 | $4,410 | 1,119 | - | - | - | - |
$6,698 816,870 kWh |
$4,410 1,119 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $10,001 Cost: $25,778 |
$6,028 | 735,183 | $3,973 | 1,008 | - | - | - | - |
$6,028 735,183 kWh |
$3,973 1,008 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $7,349 Cost: $21,884 |
$4,437 | 541,148 | $2,912 | 1,477 | - | - | - | - |
$4,437 541,148 kWh |
$2,912 1,477 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT |
Savings: $1,930,557 Cost: $208,000 |
- | - | - | - | $1,930,557 | 460,416 | - | - |
- - kWh |
- - kW-months/year |
$1,930,557 460,416 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.1121 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING |
Savings: $13,739 Cost: $3,900 |
- | - | - | - | $13,739 | 3,277 | - | - |
- - kWh |
- - kW-months/year |
$13,739 3,277 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.1121 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING |
Savings: $135,553 Cost: $58,580 |
- | - | - | - | $135,553 | 32,328 | - | - |
- - kWh |
- - kW-months/year |
$135,553 32,328 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $540,000 Cost: $125,040 |
- | - | - | - | - | - | $540,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$540,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $2,667,711 Cost: $458,450 |
$18,746 | 2,286,253 | $12,450 | 3,940 | $2,096,515 | 499,995 | $540,000 | - | $18,746 2,286,253 kWh |
$12,450 3,940 kW-months/year |
$2,096,515 499,995 MMBtu |
$540,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $558,957 Cost: $130,508 |
$1,454 | 177,252 | $837 | 245 | $16,666 | 3,974 | $540,000 | - | $1,454 177,252 kWh |
$837 245 kW-months/year |
$16,666 3,974 MMBtu |
$540,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Primary Product |