Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2001 |
Principal Product | Heat Exchanger |
NAICS | n/a |
SIC | 3443 - Fabricated Plate Work (boiler Shops) |
Sales | $1,000,000-$5,000,000 |
# of Employees | 34 |
Plant Area (Sq.Ft.) | 33,350 |
Annual Production | 420 Pieces |
Production Hrs. Annual | 2,080 |
Location (State) | OK |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $17,804 | 320,280 | kWh | $0.06 |
Electricity Fees | $313 | - | $ | - |
Natural Gas | $12,233 | 1,965 | MMBtu | $6.23 |
TOTAL ENERGY COSTS | $27,350 | |||
RECOMMENDED SAVINGS* | $17,391 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $13,102 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,592 Cost: $615 |
$223 | 6,588 | $39 | 1 | - | - | $300 | - | $1,030 | - |
$223 6,588 kWh |
$39 1 kW-months/year |
- - MMBtu |
$300 - $ |
$1,030 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $238 Cost: $1,470 |
$100 | 2,962 | $74 | 1 | - | - | - | - | $64 | - |
$100 2,962 kWh |
$74 1 kW-months/year |
- - MMBtu |
- - $ |
$64 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $129 Cost: $240 |
$129 | 3,828 | - | - | - | - | - | - | - | - |
$129 3,828 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $1,442 Cost: $200 |
$828 | 24,500 | $614 | 12 | - | - | - | - | - | - |
$828 24,500 kWh |
$614 12 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6232 INSTALL SET-BACK TIMERS |
Savings: $8,700 Cost: $1,170 |
- | - | - | - | $8,700 | 1,260 | - | - | - | - |
- - kWh |
- - kW-months/year |
$8,700 1,260 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,130 Cost: $40 |
- | - | - | - | $1,130 | 163 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,130 163 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.2176 INCREASE USE OF AUTOMATION |
Savings: $4,160 Cost: $38,900 |
- | - | - | - | - | - | $4,160 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$4,160 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $17,391 Cost: $42,635 |
$1,280 | 37,878 | $727 | 14 | $9,830 | 1,423 | $4,460 | - | $1,094 | - | $1,280 37,878 kWh |
$727 14 kW-months/year |
$9,830 1,423 MMBtu |
$4,460 - $ |
$1,094 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $13,102 Cost: $3,495 |
$1,151 | 34,050 | $727 | 14 | $9,830 | 1,423 | $300 | - | $1,094 | - | $1,151 34,050 kWh |
$727 14 kW-months/year |
$9,830 1,423 MMBtu |
$300 - $ |
$1,094 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |