Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2002 |
Principal Product | Wood Crates and Pallets |
NAICS | n/a |
SIC | 2448 - Wood Pallets And Skids |
Sales | $1,000,000-$5,000,000 |
# of Employees | 40 |
Plant Area (Sq.Ft.) | 20,000 |
Annual Production | 250,000 Pieces |
Production Hrs. Annual | 3,120 |
Location (State) | KS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $19,094 | 742,550 | kWh | $0.03 |
Electricity Demand | $12,266 | - | kW-months/year | - |
Electricity Fees | $2,404 | - | $ | - |
Natural Gas | $1,225 | 127 | MMBtu | $9.65 |
LPG | $5,959 | 694 | MMBtu | $8.59 |
TOTAL ENERGY COSTS | $41,246 | |||
RECOMMENDED SAVINGS* | $14,774 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $14,271 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6232 INSTALL SET-BACK TIMERS |
Savings: $503 Cost: $2 |
- | - | - | - | $503 | 57 | - | - | - | - |
- - kWh |
- - kW-months/year |
$503 57 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $91 Cost: $185 |
$91 | 2,496 | - | - | - | - | - | - | - | - |
$91 2,496 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $6,484 Cost: - |
- | - | $6,484 | 1,968 | - | - | - | - | - | - |
- - kWh |
$6,484 1,968 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $5,814 Cost: $8,286 |
- | - | - | - | - | - | - | - | $5,814 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$5,814 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,882 Cost: $630 |
$1,618 | 44,428 | $564 | 171 | - | - | $(-300) | - | - | - |
$1,618 44,428 kWh |
$564 171 kW-months/year |
- - MMBtu |
$(-300) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $14,774 Cost: $9,103 |
$1,709 | 46,924 | $7,048 | 2,139 | $503 | 57 | $(-300) | - | $5,814 | - | $1,709 46,924 kWh |
$7,048 2,139 kW-months/year |
$503 57 MMBtu |
$(-300) - $ |
$5,814 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $14,271 Cost: $9,101 |
$1,709 | 46,924 | $7,048 | 2,139 | - | - | $(-300) | - | $5,814 | - | $1,709 46,924 kWh |
$7,048 2,139 kW-months/year |
- - MMBtu |
$(-300) - $ |
$5,814 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Product |