Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2003 |
Principal Product | Fan Coil Units |
NAICS | 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
SIC | 3585 - Refrigeration And Heating Equipment |
Sales | $50,000,000-$100,000,000 |
# of Employees | 400 |
Plant Area (Sq.Ft.) | 161,000 |
Annual Production | 90,000 Pieces |
Production Hrs. Annual | 4,160 |
Location (State) | OK |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $158,791 | 5,446,800 | kWh | $0.03 |
Electricity Demand | $141,120 | 13,402 | kW-months/year | $10.53 |
Electricity Fees | $9,907 | - | $ | - |
Natural Gas | $53,403 | 13,224 | MMBtu | $4.04 |
TOTAL ENERGY COSTS | $45,693 | |||
RECOMMENDED SAVINGS* | $133,689 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $48,220 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $72,173 Cost: - |
- | - | $72,173 | 6,854 | - | - | - | - | - | - | - | - |
- - kWh |
$72,173 6,854 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $20,400 Cost: - |
- | - | - | - | - | - | - | - | $6,000 | - | $14,400 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$6,000 - $ |
$14,400 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $8,245 Cost: $7,483 |
- | - | - | - | $8,245 | 2,042 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$8,245 2,042 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,319 Cost: $823 |
$2,018 | 74,476 | $1,757 | 215 | - | - | - | - | $(-456) | - | - | - |
$2,018 74,476 kWh |
$1,757 215 kW-months/year |
- - MMBtu |
- - $ |
$(-456) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $1,271 Cost: $3,206 |
- | - | $1,271 | 298 | - | - | - | - | - | - | - | - |
- - kWh |
$1,271 298 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4227 USE COMPRESSOR AIR FILTERS |
Savings: $3,339 Cost: $168 |
$1,883 | 69,472 | $756 | 200 | $1,708 | 423 | - | - | $(-1,008) | - | - | - |
$1,883 69,472 kWh |
$756 200 kW-months/year |
$1,708 423 MMBtu |
- - $ |
$(-1,008) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $441 Cost: $262 |
$441 | 16,286 | - | - | - | - | - | - | - | - | - | - |
$441 16,286 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $13,061 Cost: $45,000 |
$13,061 | 481,970 | - | - | - | - | - | - | - | - | - | - |
$13,061 481,970 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.513 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS |
Savings: $11,440 Cost: $2,500 |
- | - | - | - | - | - | $11,440 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$11,440 - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $133,689 Cost: $59,442 |
$17,403 | 642,204 | $75,957 | 7,567 | $9,953 | 2,465 | $11,440 | - | $4,536 | - | $14,400 | - | $17,403 642,204 kWh |
$75,957 7,567 kW-months/year |
$9,953 2,465 MMBtu |
$11,440 - $ |
$4,536 - $ |
$14,400 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $48,220 Cost: $48,323 |
$15,079 | 556,446 | $1,757 | 215 | - | - | $11,440 | - | $5,544 | - | $14,400 | - | $15,079 556,446 kWh |
$1,757 215 kW-months/year |
- - MMBtu |
$11,440 - $ |
$5,544 - $ |
$14,400 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Primary Product |