Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2004 |
Principal Product | Pizza Crust |
NAICS | 311412 - Frozen Specialty Food Manufacturing |
SIC | 2038 - Frozen Specialties, Nec |
Sales | $5,000,000-$10,000,000 |
# of Employees | 90 |
Plant Area (Sq.Ft.) | 48,000 |
Annual Production | 12,000,000 Pounds |
Production Hrs. Annual | 4,160 |
Location (State) | OK |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $101,313 | 3,544,466 | kWh | $0.03 |
Electricity Demand | $75,406 | 9,050 | kW-months/year | $8.33 |
Electricity Fees | $50,366 | - | $ | - |
Natural Gas | $19,293 | 2,014 | MMBtu | $9.58 |
TOTAL ENERGY COSTS | $259,074 | |||
RECOMMENDED SAVINGS* | $91,295 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $17,553 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $35,493 Cost: $329,564 |
$35,493 | 553,718 | - | - | - | - | - | - | - | - | - | - | - | - |
$35,493 553,718 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $17,436 Cost: $17,500 |
- | - | - | - | - | - | $17,436 | 1,820 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$17,436 1,820 MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $1,386 Cost: $4,515 |
$1,386 | 48,444 | - | - | - | - | - | - | - | - | - | - | - | - |
$1,386 48,444 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $10,723 Cost: $21,750 |
$10,723 | 374,912 | - | - | - | - | - | - | - | - | - | - | - | - |
$10,723 374,912 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.8112 COMBINE UTILITY METERS |
Savings: $2,354 Cost: $2,546 |
- | - | - | - | $1,612 | - | - | - | - | - | $742 | - | - | - |
- - kWh |
- - kW-months/year |
$1,612 - $ |
- - MMBtu |
- - $ |
$742 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4156 ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM |
Savings: $6,830 Cost: - |
- | - | - | - | - | - | - | - | $6,830 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$6,830 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $17,073 Cost: $23,985 |
$11,472 | 178,963 | $4,296 | 516 | - | - | - | - | $4,950 | - | - | - | $(-3,645) | - |
$11,472 178,963 kWh |
$4,296 516 kW-months/year |
- - $ |
- - MMBtu |
$4,950 - $ |
- - $ |
$(-3,645) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $91,295 Cost: $399,860 |
$59,074 | 1,156,037 | $4,296 | 516 | $1,612 | - | $17,436 | 1,820 | $11,780 | - | $742 | - | $(-3,645) | - | $59,074 1,156,037 kWh |
$4,296 516 kW-months/year |
$1,612 - $ |
$17,436 1,820 MMBtu |
$11,780 - $ |
$742 - $ |
$(-3,645) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $17,553 Cost: $21,750 |
$10,723 | 374,912 | - | - | - | - | - | - | $6,830 | - | - | - | - | - | $10,723 374,912 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$6,830 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost |