IAC logo
IAC Assessment: OK0788
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: OK0788
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 2010
Principal Product Batteries
NAICS 335911 - Storage Battery Manufacturing
SIC 3692 - Primary Batteries, Dry And Wet
Sales $50,000,000-$100,000,000
# of Employees 206
Plant Area (Sq.Ft.) 150,000
Annual Production 421,000 Pieces
Production Hrs. Annual 7,488
Location (State) AR
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,094,155 21,945,600 kWh $0.05
Natural Gas $495,376 72,602 MMBtu $6.82
TOTAL ENERGY COSTS $1,589,531
RECOMMENDED SAVINGS* $124,517 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $57,362
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$285
Cost:
$451
- - $285 42 -
-
kWh
$285
42
MMBtu
02: 2.1121 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING Savings:
$29,667
Cost:
$2,587
- - $29,667 4,350 -
-
kWh
$29,667
4,350
MMBtu
03: 2.1121 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING Savings:
$1,568
Cost:
$1,078
- - $1,568 230 -
-
kWh
$1,568
230
MMBtu
04: 2.1135 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY Savings:
$3,625
Cost:
$1,176
- - $3,625 532 -
-
kWh
$3,625
532
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,103
Cost:
$5,543
$1,103 22,117 - - $1,103
22,117
kWh
-
-
MMBtu
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,350
Cost:
$8,818
$2,350 47,129 - - $2,350
47,129
kWh
-
-
MMBtu
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$35,265
Cost:
$98,109
$35,265 707,317 - - $35,265
707,317
kWh
-
-
MMBtu
08: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$441
Cost:
$1,170
$441 8,833 - - $441
8,833
kWh
-
-
MMBtu
09: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$5,877
Cost:
-
$5,877 117,540 - - $5,877
117,540
kWh
-
-
MMBtu
10: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$15,837
Cost:
$12,000
$15,837 303,085 - - $15,837
303,085
kWh
-
-
MMBtu
11: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$6,106
Cost:
$101,906
$6,106 122,129 - - $6,106
122,129
kWh
-
-
MMBtu
12: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$22,393
Cost:
$7,656
$22,393 447,861 - - $22,393
447,861
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$124,517
Cost:
$240,494
$89,372 1,776,011 $35,145 5,154 $89,372
1,776,011
kWh
$35,145
5,154
MMBtu
TOTAL IMPLEMENTED Savings:
$57,362
Cost:
$120,554
$53,452 1,057,531 $3,910 574 $53,452
1,057,531
kWh
$3,910
574
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas