Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 2010
Principal Product Hydraulic Cylinder
NAICS 333995 - Fluid Power Cylinder and Actuator Manufacturing
SIC 3593 - Fluid Power Cylinders & Actuators
Sales $5,000,000-$10,000,000
# of Employees 87
Plant Area (Sq.Ft.) 132,500
Annual Production 92,000 Pieces
Production Hrs. Annual 4,355
Location (State) KS
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $137,339 1,917,600 kWh $0.07
Electricity Demand $40,301 8,699 kW-months/year $4.63
Natural Gas $61,884 9,482 MMBtu $6.53
TOTAL ENERGY COSTS $239,524
RECOMMENDED SAVINGS* $38,855 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $13,532
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$12,132
Cost:
$75,405
- - $12,132 1,317 -
-
kWh
$12,132
1,317
MMBtu
02: 2.6232 INSTALL SET-BACK TIMERS Savings:
$2,786
Cost:
$3,239
- - $2,786 414 -
-
kWh
$2,786
414
MMBtu
03: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$10,317
Cost:
$159,840
- - $10,317 1,533 -
-
kWh
$10,317
1,533
MMBtu
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,034
Cost:
$12,733
$3,034 42,373 - - $3,034
42,373
kWh
-
-
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$7,300
Cost:
$68,625
$7,300 101,962 - - $7,300
101,962
kWh
-
-
MMBtu
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$853
Cost:
$4,978
$853 11,919 - - $853
11,919
kWh
-
-
MMBtu
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$653
Cost:
$3,006
- - $653 97 -
-
kWh
$653
97
MMBtu
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,400
Cost:
$841
$1,400 19,564 - - $1,400
19,564
kWh
-
-
MMBtu
09: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$380
Cost:
$2,280
$380 5,318 - - $380
5,318
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$38,855
Cost:
$330,947
$12,967 181,136 $25,888 3,361 $12,967
181,136
kWh
$25,888
3,361
MMBtu
TOTAL IMPLEMENTED Savings:
$13,532
Cost:
$76,246
$1,400 19,564 $12,132 1,317 $1,400
19,564
kWh
$12,132
1,317
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas