Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 2010
Principal Product Refrigeration Units
NAICS 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen
SIC 3585 - Refrigeration And Heating Equipment
Sales $10,000,000-$50,000,000
# of Employees 240
Plant Area (Sq.Ft.) 220,000
Annual Production 14,000 Pieces
Production Hrs. Annual 4,680
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $186,802 3,045,312 kWh $0.06
Natural Gas $54,522 7,964 MMBtu $6.85
TOTAL ENERGY COSTS $241,324
RECOMMENDED SAVINGS* $37,663 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $7,326
#|Description Savings
Cost
Status Electricity Usage Electricity Fees Natural Gas Electricity Usage Electricity Fees Natural Gas
$ kWh $ $ $ MMBtu
01: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$16,798
Cost:
$29,735
- - $16,798 - - - -
-
kWh
$16,798
-
$
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,028
Cost:
$14,578
$3,028 49,401 - - - - $3,028
49,401
kWh
-
-
$
-
-
MMBtu
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,129
Cost:
$5,526
$1,129 18,421 - - - - $1,129
18,421
kWh
-
-
$
-
-
MMBtu
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$2,660
Cost:
$1,378
- - - - $2,660 375 -
-
kWh
-
-
$
$2,660
375
MMBtu
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,383
Cost:
$500
$2,383 38,877 - - - - $2,383
38,877
kWh
-
-
$
-
-
MMBtu
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$851
Cost:
$217
$851 13,885 - - - - $851
13,885
kWh
-
-
$
-
-
MMBtu
07: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$10,028
Cost:
$23,000
- - - - $10,028 1,414 -
-
kWh
-
-
$
$10,028
1,414
MMBtu
08: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$786
Cost:
$1,850
- - - - $786 110 -
-
kWh
-
-
$
$786
110
MMBtu
TOTAL RECOMMENDED Savings:
$37,663
Cost:
$76,784
$7,391 120,584 $16,798 - $13,474 1,899 $7,391
120,584
kWh
$16,798
-
$
$13,474
1,899
MMBtu
TOTAL IMPLEMENTED Savings:
$7,326
Cost:
$22,454
$6,540 106,699 - - $786 110 $6,540
106,699
kWh
-
-
$
$786
110
MMBtu
Savings
Cost
$ kWh $ $ $ MMBtu
Electricity Usage Electricity Fees Natural Gas Electricity Usage Electricity Fees Natural Gas