Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 2011
Principal Product Motors
NAICS 333612 - Speed Changer, Industrial High-Speed Drive, and Gear Manufacturing
SIC 3566 - Speed Changers, Drives, And Gears
Sales $100,000,000-$500,000,000
# of Employees 390
Plant Area (Sq.Ft.) 225,000
Annual Production 480,000 Pieces
Production Hrs. Annual 8,760
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,010,822 22,147,200 kWh $0.05
Natural Gas $124,845 24,442 MMBtu $5.11
TOTAL ENERGY COSTS $1,135,667
RECOMMENDED SAVINGS* $121,259 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $46,568
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING Savings:
$20,409
Cost:
$71,773
$20,409 443,664 - - $20,409
443,664
kWh
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$245
Cost:
$1,488
$245 5,320 - - $245
5,320
kWh
-
-
MMBtu
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$391
Cost:
$456
$391 8,504 - - $391
8,504
kWh
-
-
MMBtu
04: 2.7122 DISCONNECT BALLASTS Savings:
$481
Cost:
$921
$481 10,452 - - $481
10,452
kWh
-
-
MMBtu
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$17,462
Cost:
-
$17,462 379,600 - - $17,462
379,600
kWh
-
-
MMBtu
06: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$13,197
Cost:
$9,150
$13,197 286,902 - - $13,197
286,902
kWh
-
-
MMBtu
07: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$17,005
Cost:
$315,900
$17,005 369,672 - - $17,005
369,672
kWh
-
-
MMBtu
08: 2.1224 REPLACE BOILER Savings:
$26,135
Cost:
$24,220
- - $26,135 5,125 -
-
kWh
$26,135
5,125
MMBtu
09: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$4,244
Cost:
$11,700
- - $4,244 832 -
-
kWh
$4,244
832
MMBtu
10: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$18,037
Cost:
-
$18,037 392,098 - - $18,037
392,098
kWh
-
-
MMBtu
11: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,760
Cost:
$1,338
$1,760 38,250 - - $1,760
38,250
kWh
-
-
MMBtu
12: 2.2511 INSULATE BARE EQUIPMENT Savings:
$1,893
Cost:
$2,263
- - $1,893 371 -
-
kWh
$1,893
371
MMBtu
TOTAL RECOMMENDED Savings:
$121,259
Cost:
$439,209
$88,987 1,934,462 $32,272 6,328 $88,987
1,934,462
kWh
$32,272
6,328
MMBtu
TOTAL IMPLEMENTED Savings:
$46,568
Cost:
$27,502
$20,433 444,172 $26,135 5,125 $20,433
444,172
kWh
$26,135
5,125
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas