Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 2011
Principal Product Filters
NAICS 333413 - Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing
SIC 3564 - Blowers And Fans
Sales $10,000,000-$50,000,000
# of Employees 250
Plant Area (Sq.Ft.) 475,000
Annual Production 5,200,000 Pieces
Production Hrs. Annual 8,760
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $280,627 4,088,560 kWh $0.07
Natural Gas $26,063 4,305 MMBtu $6.05
TOTAL ENERGY COSTS $306,690
RECOMMENDED SAVINGS* $65,403 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $14,820
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$6,438
Cost:
$510
$6,438 93,852 - - $6,438
93,852
kWh
-
-
MMBtu
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$1,812
Cost:
$1,220
- - $1,812 299 -
-
kWh
$1,812
299
MMBtu
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,613
Cost:
$2,745
$1,613 23,526 - - $1,613
23,526
kWh
-
-
MMBtu
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$728
Cost:
$2,751
$728 10,612 - - $728
10,612
kWh
-
-
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$29,469
Cost:
$55,540
$29,469 429,581 - - $29,469
429,581
kWh
-
-
MMBtu
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$12,965
Cost:
$47,375
$12,965 189,000 - - $12,965
189,000
kWh
-
-
MMBtu
07: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$5,011
Cost:
$23,400
$755 11,003 $4,256 704 $755
11,003
kWh
$4,256
704
MMBtu
08: 2.2691 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS Savings:
$2,546
Cost:
$12,837
$2,546 37,121 - - $2,546
37,121
kWh
-
-
MMBtu
09: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$1,450
Cost:
$4,260
$1,450 21,141 - - $1,450
21,141
kWh
-
-
MMBtu
10: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$3,371
Cost:
-
$3,371 49,140 - - $3,371
49,140
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$65,403
Cost:
$150,638
$59,335 864,976 $6,068 1,003 $59,335
864,976
kWh
$6,068
1,003
MMBtu
TOTAL IMPLEMENTED Savings:
$14,820
Cost:
$23,910
$10,564 153,995 $4,256 704 $10,564
153,995
kWh
$4,256
704
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas