IAC logo
IAC Assessment: OK0847
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: OK0847
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 2013
Principal Product Aircraft Parts
NAICS 336411 - Aircraft Manufacturing
SIC 3728 - Aircraft Parts And Equipment, Nec
Sales $10,000,000-$50,000,000
# of Employees 100
Plant Area (Sq.Ft.) 60,000
Annual Production 50,000 Pieces
Production Hrs. Annual 2,630
Location (State) KS
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $115,834 1,781,488 kWh $0.07
Electricity Demand $87,273 12,675 kW-months/year $6.89
Natural Gas $23,074 2,662 MMBtu $8.67
TOTAL ENERGY COSTS $226,181
RECOMMENDED SAVINGS* $32,759 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $5,794
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Natural Gas Electricity Usage Electricity Demand Electricity Fees Natural Gas
$ kWh $ kW-months/year $ $ $ MMBtu
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,232
Cost:
-
$779 11,990 $453 66 - - - - $779
11,990
kWh
$453
66
kW-months/year
-
-
$
-
-
MMBtu
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$623
Cost:
$180
$623 9,584 - - - - - - $623
9,584
kWh
-
-
kW-months/year
-
-
$
-
-
MMBtu
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,698
Cost:
$29,880
$2,530 38,930 $1,168 170 - - - - $2,530
38,930
kWh
$1,168
170
kW-months/year
-
-
$
-
-
MMBtu
04: 2.1121 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING Savings:
$1,473
Cost:
$1,128
$1,473 22,655 - - - - - - $1,473
22,655
kWh
-
-
kW-months/year
-
-
$
-
-
MMBtu
05: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$13,014
Cost:
$32,500
- - - - - - $13,014 1,501 -
-
kWh
-
-
kW-months/year
-
-
$
$13,014
1,501
MMBtu
06: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$12,719
Cost:
$11,540
- - - - $12,719 - - - -
-
kWh
-
-
kW-months/year
$12,719
-
$
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$32,759
Cost:
$75,228
$5,406 83,159 $1,620 236 $12,719 - $13,014 1,501 $5,406
83,159
kWh
$1,620
236
kW-months/year
$12,719
-
$
$13,014
1,501
MMBtu
TOTAL IMPLEMENTED Savings:
$5,794
Cost:
$31,188
$4,626 71,169 $1,168 170 - - - - $4,626
71,169
kWh
$1,168
170
kW-months/year
-
-
$
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ $ $ MMBtu
Electricity Usage Electricity Demand Electricity Fees Natural Gas Electricity Usage Electricity Demand Electricity Fees Natural Gas