Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 2013
Principal Product Packaged paper towels, toilet paper, paper napkins
NAICS 322220 - Paper Bag and Coated and Treated Paper Manufacturing
SIC 2676 - Sanitary Paper Products
Sales $10,000,000-$50,000,000
# of Employees 80
Plant Area (Sq.Ft.) 323,000
Annual Production 10,500,000 Units
Production Hrs. Annual 8,760
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $276,930 5,308,800 kWh $0.05
Electricity Demand $45,831 9,605 kW-months/year $4.77
Natural Gas $3,992 524 MMBtu $7.62
TOTAL ENERGY COSTS $326,753
RECOMMENDED SAVINGS* $126,966 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $804
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$40,042
Cost:
$20,360
$40,042 770,042 - - - - $40,042
770,042
kWh
-
-
kW-months/year
-
-
MMBtu
02: 2.6232 INSTALL SET-BACK TIMERS Savings:
$1,493
Cost:
$172
$1,393 26,781 $100 21 - - $1,393
26,781
kWh
$100
21
kW-months/year
-
-
MMBtu
03: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$5,082
Cost:
$19,800
$4,572 87,913 $511 107 - - $4,572
87,913
kWh
$511
107
kW-months/year
-
-
MMBtu
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$804
Cost:
$1,338
$804 15,465 - - - - $804
15,465
kWh
-
-
kW-months/year
-
-
MMBtu
05: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD Savings:
$32,018
Cost:
$268,800
$27,251 524,058 $4,767 999 - - $27,251
524,058
kWh
$4,767
999
kW-months/year
-
-
MMBtu
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$13,454
Cost:
$63,252
$13,316 256,072 $138 29 - - $13,316
256,072
kWh
$138
29
kW-months/year
-
-
MMBtu
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$24,717
Cost:
$66,757
$24,573 472,565 $143 30 - - $24,573
472,565
kWh
$143
30
kW-months/year
-
-
MMBtu
08: 2.7122 DISCONNECT BALLASTS Savings:
$6,565
Cost:
$3,020
$6,498 124,969 $67 14 - - $6,498
124,969
kWh
$67
14
kW-months/year
-
-
MMBtu
09: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$2,791
Cost:
$1,220
- - - - $2,791 366 -
-
kWh
-
-
kW-months/year
$2,791
366
MMBtu
TOTAL RECOMMENDED Savings:
$126,966
Cost:
$444,719
$118,449 2,277,865 $5,726 1,200 $2,791 366 $118,449
2,277,865
kWh
$5,726
1,200
kW-months/year
$2,791
366
MMBtu
TOTAL IMPLEMENTED Savings:
$804
Cost:
$1,338
$804 15,465 - - - - $804
15,465
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas