Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 2013
Principal Product Industrial and Automotive Seals & Gaskets
NAICS 336350 - Motor Vehicle Transmission and Power Train Parts Manufacturing
SIC 3714 - Motor Vehicle Parts And Accessories
Sales $50,000,000-$100,000,000
# of Employees 235
Plant Area (Sq.Ft.) 89,000
Annual Production 30,000,000 Pieces
Production Hrs. Annual 8,760
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $418,864 11,046,000 kWh $0.04
Electricity Demand $213,109 24,665 kW-months/year $8.64
Electricity Fees $(-126,654) - $ -
Natural Gas $16,443 5,447 MMBtu $3.02
TOTAL ENERGY COSTS $521,762
RECOMMENDED SAVINGS* $168,556 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $6,427
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$6,427
Cost:
$1,250
$6,427 169,140 - - - - $6,427
169,140
kWh
-
-
kW-months/year
-
-
MMBtu
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,478
Cost:
$1,026
$1,478 38,882 - - - - $1,478
38,882
kWh
-
-
kW-months/year
-
-
MMBtu
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$1,425
Cost:
$1,378
- - - - $1,425 472 -
-
kWh
-
-
kW-months/year
$1,425
472
MMBtu
04: 2.7242 CHANGE ZONE REHEAT COILS TO VARIABLE AIR VOLUME BOXES Savings:
$834
Cost:
$3,110
$606 15,959 $228 26 - - $606
15,959
kWh
$228
26
kW-months/year
-
-
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,689
Cost:
$13,383
$2,047 53,856 $642 74 - - $2,047
53,856
kWh
$642
74
kW-months/year
-
-
MMBtu
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$377
Cost:
$9,558
$377 9,914 - - - - $377
9,914
kWh
-
-
kW-months/year
-
-
MMBtu
07: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$22,838
Cost:
$54,080
$12,840 337,891 $9,998 1,157 - - $12,840
337,891
kWh
$9,998
1,157
kW-months/year
-
-
MMBtu
08: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$960
Cost:
$1,500
$960 25,272 - - - - $960
25,272
kWh
-
-
kW-months/year
-
-
MMBtu
09: 2.7211 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS Savings:
$12,086
Cost:
$2,710
$8,699 228,916 $3,387 392 - - $8,699
228,916
kWh
$3,387
392
kW-months/year
-
-
MMBtu
10: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD Savings:
$53,906
Cost:
$518,400
$38,801 1,021,066 $15,106 1,748 - - $38,801
1,021,066
kWh
$15,106
1,748
kW-months/year
-
-
MMBtu
11: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$65,536
Cost:
$250,000
$43,141 1,135,296 $22,395 2,592 - - $43,141
1,135,296
kWh
$22,395
2,592
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$168,556
Cost:
$856,395
$115,375 3,036,192 $51,756 5,990 $1,425 472 $115,375
3,036,192
kWh
$51,756
5,990
kW-months/year
$1,425
472
MMBtu
TOTAL IMPLEMENTED Savings:
$6,427
Cost:
$1,250
$6,427 169,140 - - - - $6,427
169,140
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas