Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 2014
Principal Product Bearing housings
NAICS 332991 - Ball and Roller Bearing Manufacturing
SIC 3562 - Ball And Roller Bearings
Sales $10,000,000-$50,000,000
# of Employees 48
Plant Area (Sq.Ft.) 40,000
Annual Production 38,000 Pieces
Production Hrs. Annual 4,680
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $67,985 935,500 kWh $0.07
Electricity Fees $40,439 - $ -
Natural Gas $5,182 924 MMBtu $5.61
TOTAL ENERGY COSTS $113,607
RECOMMENDED SAVINGS* $17,606 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $6,765
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.6232 INSTALL SET-BACK TIMERS Savings:
$1,092
Cost:
$676
$761 10,423 $331 59 $761
10,423
kWh
$331
59
MMBtu
02: 2.7211 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS Savings:
$774
Cost:
$280
$774 10,608 - - $774
10,608
kWh
-
-
MMBtu
03: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$2,523
Cost:
$5,398
$2,523 34,560 - - $2,523
34,560
kWh
-
-
MMBtu
04: 2.6232 INSTALL SET-BACK TIMERS Savings:
$701
Cost:
$2,100
- - $701 125 -
-
kWh
$701
125
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$6,148
Cost:
$24,197
$6,148 84,219 - - $6,148
84,219
kWh
-
-
MMBtu
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,142
Cost:
$3,353
$1,142 15,643 - - $1,142
15,643
kWh
-
-
MMBtu
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$507
Cost:
$4,399
$507 6,945 - - $507
6,945
kWh
-
-
MMBtu
08: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$2,956
Cost:
$4,399
$2,956 40,490 - - $2,956
40,490
kWh
-
-
MMBtu
09: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$521
Cost:
$689
- - $521 93 -
-
kWh
$521
93
MMBtu
10: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,242
Cost:
$500
$1,242 17,020 - - $1,242
17,020
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$17,606
Cost:
$45,991
$16,053 219,908 $1,553 277 $16,053
219,908
kWh
$1,553
277
MMBtu
TOTAL IMPLEMENTED Savings:
$6,765
Cost:
$7,955
$5,733 78,541 $1,032 184 $5,733
78,541
kWh
$1,032
184
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas