Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2015 |
Principal Product | Juice Energy Products |
NAICS | 311421 - Fruit and Vegetable Canning |
SIC | 2033 - Canned Fruits And Vegetables |
Sales | $10,000,000-$50,000,000 |
# of Employees | 225 |
Plant Area (Sq.Ft.) | 460,000 |
Annual Production | 178,000,000 Pieces |
Production Hrs. Annual | 8,760 |
Location (State) | OK |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $770,961 | 14,325,944 | kWh | $0.05 |
Electricity Demand | $262,765 | 27,230 | kW-months/year | $9.65 |
Natural Gas | $410,735 | 85,088 | MMBtu | $4.83 |
TOTAL ENERGY COSTS | $1,444,461 | |||
RECOMMENDED SAVINGS* | $237,191 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $117,364 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $8,390 Cost: $2,440 |
- | - | - | - | - | - | $8,390 | 1,737 |
- - kWh |
- - kW-months/year |
- - $ |
$8,390 1,737 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $42,177 Cost: $162,050 |
$21,936 | 406,213 | $20,242 | 2,100 | - | - | - | - |
$21,936 406,213 kWh |
$20,242 2,100 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $25,309 Cost: $1,250 |
$25,309 | 468,679 | - | - | - | - | - | - |
$25,309 468,679 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,605 Cost: $6,953 |
$1,737 | 32,175 | $868 | 90 | - | - | - | - |
$1,737 32,175 kWh |
$868 90 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $70,459 Cost: $247,939 |
$56,637 | 1,048,834 | $13,822 | 1,440 | - | - | - | - |
$56,637 1,048,834 kWh |
$13,822 1,440 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,664 Cost: $8,092 |
$1,664 | 30,807 | - | - | - | - | - | - |
$1,664 30,807 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $2,710 Cost: $2,471 |
$1,882 | 34,843 | - | - | - | - | $829 | 172 |
$1,882 34,843 kWh |
- - kW-months/year |
- - $ |
$829 172 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $18,886 Cost: $375 |
- | - | - | - | - | - | $18,886 | 3,906 |
- - kWh |
- - kW-months/year |
- - $ |
$18,886 3,906 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $53,631 Cost: $44,000 |
- | - | - | - | - | - | $53,631 | 11,104 |
- - kWh |
- - kW-months/year |
- - $ |
$53,631 11,104 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $317 Cost: $46 |
- | - | - | - | - | - | $317 | 66 |
- - kWh |
- - kW-months/year |
- - $ |
$317 66 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $11,042 Cost: $47,988 |
- | - | - | - | $11,042 | - | - | - |
- - kWh |
- - kW-months/year |
$11,042 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $237,191 Cost: $523,604 |
$109,164 | 2,021,551 | $34,932 | 3,630 | $11,042 | - | $82,054 | 16,985 | $109,164 2,021,551 kWh |
$34,932 3,630 kW-months/year |
$11,042 - $ |
$82,054 16,985 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $117,364 Cost: $252,035 |
$83,828 | 1,552,356 | $13,822 | 1,440 | - | - | $19,715 | 4,078 | $83,828 1,552,356 kWh |