Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2015 |
Principal Product | Aircraft manufacturing |
NAICS | 336413 - Other Aircraft Parts and Auxiliary Equipment Manufacturing |
SIC | 3728 - Aircraft Parts And Equipment, Nec |
Sales | $100,000,000-$500,000,000 |
# of Employees | 411 |
Plant Area (Sq.Ft.) | 356,250 |
Annual Production | 2,263,800 Pieces |
Production Hrs. Annual | 8,760 |
Location (State) | KS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $614,518 | 10,078,080 | kWh | $0.06 |
Electricity Demand | $298,320 | 23,773 | kW-months/year | $12.55 |
Natural Gas | $40,592 | 4,684 | MMBtu | $8.67 |
TOTAL ENERGY COSTS | $953,430 | |||
RECOMMENDED SAVINGS* | $152,178 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $83,574 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $58,176 Cost: $103,015 |
$45,908 | 752,589 | $12,268 | 978 | - | - | - | - | - | - |
$45,908 752,589 kWh |
$12,268 978 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $17,688 Cost: $25,096 |
$17,688 | 289,961 | - | - | - | - | - | - | - | - |
$17,688 289,961 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,867 Cost: $20,538 |
$4,947 | 81,099 | $1,920 | 153 | - | - | - | - | - | - |
$4,947 81,099 kWh |
$1,920 153 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,060 Cost: $24,180 |
$6,060 | 99,341 | - | - | - | - | - | - | - | - |
$6,060 99,341 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $10,077 Cost: $6,900 |
$10,077 | 165,189 | - | - | - | - | - | - | - | - |
$10,077 165,189 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $7,439 Cost: $14,107 |
$7,439 | 121,946 | - | - | - | - | - | - | - | - |
$7,439 121,946 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $674 Cost: $382 |
$674 | 11,049 | - | - | - | - | - | - | - | - |
$674 11,049 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $4,441 Cost: $14,342 |
$4,441 | 72,796 | - | - | - | - | - | - | - | - |
$4,441 72,796 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $6,741 Cost: $3,938 |
$6,741 | 110,501 | - | - | - | - | - | - | - | - |
$6,741 110,501 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $8,266 Cost: $63,126 |
$8,266 | 135,505 | - | - | - | - | - | - | - | - |
$8,266 135,505 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7211 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS |
Savings: $1,720 Cost: $3,060 |
$4,780 | 78,355 | - | - | - | - | - | - | $(-3,060) | - |
$4,780 78,355 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$(-3,060) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.2491 USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING |
Savings: $2,345 Cost: $5,403 |
$154 | 2,532 | $552 | 44 | - | - | $1,639 | 189 | - | - |
$154 2,532 kWh |
$552 44 kW-months/year |
- - $ |
$1,639 189 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.2491 USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING |
Savings: $12,313 Cost: $21,480 |
$8,473 | 138,905 | $3,840 | 306 | - | - | - | - | - | - |
$8,473 138,905 kWh |
$3,840 306 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $9,371 Cost: $14,014 |
- | - | - | - | $9,371 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$9,371 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $152,178 Cost: $319,581 |
$125,648 | 2,059,768 | $18,580 | 1,481 | $9,371 | - | $1,639 | 189 | $(-3,060) | - | $125,648 2,059,768 kWh |
$18,580 1,481 kW-months/year |
$9,371 - $ |
$1,639 189 MMBtu |
$(-3,060) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $83,574 Cost: $158,075 |
$72,446 | 1,187,622 | $14,188 | 1,131 | - | - | - | - | $(-3,060) | - | $72,446 1,187,622 kWh |
$14,188 1,131 kW-months/year |
- - $ |
- - MMBtu |
$(-3,060) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes |