Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2015 |
Principal Product | Fiberglass Tanks |
NAICS | 325991 - Custom Compounding of Purchased Resins |
SIC | 3069 - Fabricated Rubber Products, Nec |
Sales | $5,000,000-$10,000,000 |
# of Employees | 80 |
Plant Area (Sq.Ft.) | 152,739 |
Annual Production | 175 Pieces |
Production Hrs. Annual | 2,340 |
Location (State) | AR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $44,868 | 946,880 | kWh | $0.05 |
Electricity Demand | $28,233 | 3,175 | kW-months/year | $8.89 |
Electricity Fees | $8,706 | - | $ | - |
Natural Gas | $63,217 | 8,657 | MMBtu | $7.30 |
TOTAL ENERGY COSTS | $158,392 | |||
RECOMMENDED SAVINGS* | $26,144 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $19,125 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,019 Cost: $6,287 |
$3,579 | 75,498 | $3,440 | 387 | - | - | - | - | - | - |
$3,579 75,498 kWh |
$3,440 387 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $4,154 Cost: $72 |
- | - | - | - | - | - | - | - | $4,154 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$4,154 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $537 Cost: $55 |
$537 | 11,320 | - | - | - | - | - | - | - | - |
$537 11,320 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $4,875 Cost: $2,000 |
- | - | - | - | - | - | $4,875 | 563 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$4,875 563 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $689 Cost: $577 |
$689 | 14,545 | - | - | - | - | - | - | - | - |
$689 14,545 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2211 USE OPTIMUM TEMPERATURE |
Savings: $8,870 Cost: $180 |
- | - | - | - | $8,870 | 1,215 | - | - | - | - |
- - kWh |
- - kW-months/year |
$8,870 1,215 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $26,144 Cost: $9,171 |
$4,805 | 101,363 | $3,440 | 387 | $8,870 | 1,215 | $4,875 | 563 | $4,154 | - | $4,805 101,363 kWh |
$3,440 387 kW-months/year |
$8,870 1,215 MMBtu |
$4,875 563 Tgal |
$4,154 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $19,125 Cost: $2,884 |
$1,226 | 25,865 | - | - | $8,870 | 1,215 | $4,875 | 563 | $4,154 | - | $1,226 25,865 kWh |
- - kW-months/year |
$8,870 1,215 MMBtu |
$4,875 563 Tgal |
$4,154 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes |