Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2017 |
Principal Product | Oil field equipment |
NAICS | 333132 - Oil and Gas Field Machinery and Equipment Manufacturing |
SIC | 3533 - Oil And Gas Field Machinery |
Sales | >$500,000,000 |
# of Employees | 635 |
Plant Area (Sq.Ft.) | 727,191 |
Annual Production | 1,000,000 Units |
Production Hrs. Annual | 8,760 |
Location (State) | OK |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $687,451 | 25,461,155 | kWh | $0.03 |
Electricity Demand | $417,116 | 107,546 | kW-months/year | $3.88 |
Natural Gas | $748,631 | 119,781 | MMBtu | $6.25 |
TOTAL ENERGY COSTS | $1,853,198 | |||
RECOMMENDED SAVINGS* | $337,800 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $201,958 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1224 REPLACE BOILER |
Savings: $125,000 Cost: $442,000 |
- | - | - | - | - | - | $125,000 | 20,000 |
- - kWh |
- - kW-months/year |
- - $ |
$125,000 20,000 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8115 BASE UTILITY CHARGES ON USAGE RATHER THAN AREA OCCUPIED |
Savings: $113,700 Cost: $24,000 |
- | - | - | - | $113,700 | - | - | - |
- - kWh |
- - kW-months/year |
$113,700 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $74,450 Cost: $305,694 |
$49,270 | 1,824,833 | $25,180 | 3,476 | - | - | - | - |
$49,270 1,824,833 kWh |
$25,180 3,476 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,526 Cost: $21,137 |
$2,335 | 86,468 | $1,191 | 164 | - | - | - | - |
$2,335 86,468 kWh |
$1,191 164 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $7,886 Cost: - |
$5,800 | 214,893 | $2,086 | 288 | - | - | - | - |
$5,800 214,893 kWh |
$2,086 288 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $6,570 Cost: $17,250 |
$6,570 | 243,310 | - | - | - | - | - | - |
$6,570 243,310 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $3,676 Cost: $17,550 |
$3,676 | 136,172 | - | - | - | - | - | - |
$3,676 136,172 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2514 COVER OPEN TANKS |
Savings: $2,956 Cost: $1,250 |
- | - | - | - | - | - | $2,956 | 473 |
- - kWh |
- - kW-months/year |
- - $ |
$2,956 473 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.1131 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC |
Savings: $36 Cost: $100 |
- | - | - | - | - | - | $36 | 6 |
- - kWh |
- - kW-months/year |
- - $ |
$36 6 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $337,800 Cost: $828,981 |
$67,651 | 2,505,676 | $28,457 | 3,928 | $113,700 | - | $127,992 | 20,479 | $67,651 2,505,676 kWh |
$28,457 3,928 kW-months/year |
$113,700 - $ |
$127,992 20,479 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $201,958 Cost: $385,731 |
$61,851 | 2,290,783 | $26,371 | 3,640 | $113,700 | - | $36 | 6 | $61,851 2,290,783 kWh |
$26,371 3,640 kW-months/year |
$113,700 - $ |
$36 6 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |