Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2018 |
Principal Product | Glass containers |
NAICS | 327213 - Glass Container Manufacturing |
SIC | 3221 - Glass Containers |
Sales | $10,000,000-$50,000,000 |
# of Employees | 250 |
Plant Area (Sq.Ft.) | 520,000 |
Annual Production | 730,000,000 Units |
Production Hrs. Annual | 8,760 |
Location (State) | OK |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $2,485,950 | 71,371,200 | kWh | $0.03 |
Electricity Demand | $594,657 | 108,337 | kW-months/year | $5.49 |
Natural Gas | $2,717,617 | 879,684 | MMBtu | $3.09 |
TOTAL ENERGY COSTS | $5,798,224 | |||
RECOMMENDED SAVINGS* | $534,717 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $124,716 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $124,716 Cost: $75,000 |
$102,657 | 2,933,069 | $22,058 | 4,018 | - | - |
$102,657 2,933,069 kWh |
$22,058 4,018 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $7,815 Cost: - |
$6,433 | 183,796 | $1,382 | 252 | - | - |
$6,433 183,796 kWh |
$1,382 252 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $16,309 Cost: $4,937 |
$16,309 | 465,964 | - | - | - | - |
$16,309 465,964 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $21,343 Cost: $69,050 |
$17,568 | 501,948 | $3,775 | 688 | - | - |
$17,568 501,948 kWh |
$3,775 688 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2421 INSTALL WASTE HEAT BOILER TO PROVIDE DIRECT POWER |
Savings: $353,111 Cost: $2,500,000 |
$290,657 | 8,304,480 | $62,454 | 11,376 | - | - |
$290,657 8,304,480 kWh |
$62,454 11,376 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $11,423 Cost: $50,570 |
- | - | - | - | $11,423 | - |
- - kWh |
- - kW-months/year |
$11,423 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $534,717 Cost: $2,699,557 |
$433,624 | 12,389,257 | $89,670 | 16,334 | $11,423 | - | $433,624 12,389,257 kWh |
$89,670 16,334 kW-months/year |
$11,423 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $124,716 Cost: $75,000 |
$102,657 | 2,933,069 | $22,058 | 4,018 | - | - | $102,657 2,933,069 kWh |
$22,058 4,018 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees |