Select a Center

Arizona State University
Boise State University
Case Western Reserve University
Clemson University
Colorado State University
Georgia Institute of Technology
Indiana University-Purdue University
Lehigh University
Louisiana State University
North Carolina State
Oklahoma State University
Oregon State University
San Diego State University
San Francisco State University
Syracuse University
Tennessee Technological University
Texas A&M, College Station
University of Alabama
University of Dayton
University of Delaware
University of Florida
University of Illinois, Chicago
University of Kentucky
University of Massachusetts
University of Miami
University of Missouri-Columbia
University of Nebraska–Lincoln
University of Texas Rio Grande Valley
University of Utah
University of Wisconsin, Milwaukee
West Virginia University
IAC logo
IAC Assessment: OK1028
Sponsored by:
EERE AMO
IAC logo
IAC Assessment: OK1028
Due to University and State restrictions around the country, all IAC assessment activities are temporarily on hold.
Click here for details about Coronavirus (COVID-19) Recovery Support programs
IAC Center Oklahoma State University
Assessment Year
Principal Product carbonated beverages
NAICS 312111 - Soft Drink Manufacturing
SIC 2086 - Bottled And Canned Soft Drinks
Sales $85,000,000
# of Employees 100
Plant Area (Sq.Ft.) 152,000
Annual Production 48,000 Thousand Gallons
Production Hrs. Annual 7,488
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $556,784 11,248,191 kWh $0.05
Electricity Demand $151,971 27,400 kW/month $5.55
Natural Gas $89,196 24,132 MMBtu $3.70
TOTAL ENERGY COSTS $797,951
RECOMMENDED SAVINGS* $13,025 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW/month $ MMBtu
01: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$5,729
Cost:
$1,500
- - - - $5,729 1,549 -
-
kWh
-
-
kW/month
$5,729
1,549
MMBtu
02: 2.2425 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER Savings:
$2,193
Cost:
$3,750
- - - - $2,193 593 -
-
kWh
-
-
kW/month
$2,193
593
MMBtu
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,990
Cost:
$3,313
$1,704 34,784 $286 52 - - $1,704
34,784
kWh
$286
52
kW/month
-
-
MMBtu
04: 2.2511 INSULATE BARE EQUIPMENT Savings:
$53
Cost:
$111
$53 1,074 - - - - $53
1,074
kWh
-
-
kW/month
-
-
MMBtu
05: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$2,802
Cost:
$8,260
$2,802 57,188 - - - - $2,802
57,188
kWh
-
-
kW/month
-
-
MMBtu
06: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$258
Cost:
$616
$258 5,263 - - - - $258
5,263
kWh
-
-
kW/month
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$13,025
Cost:
$17,550
$4,817 98,309 $286 52 $7,922 2,142 $4,817
98,309
kWh
$286
52
kW/month
$7,922
2,142
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW/month
-
-
MMBtu
Savings
Cost
$ kWh $ kW/month $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas