Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 2021
Principal Product educated students
NAICS 611210 - Junior Colleges
SIC 8222 - Junior Colleges
Sales $10,000,000-$50,000,000
# of Employees 490
Plant Area (Sq.Ft.) 492,653
Annual Production 8,404 Units
Production Hrs. Annual 3,216
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $321,563 7,478,200 kWh $0.04
Electricity Demand $102,521 19,056 kW-months/year $5.38
Electricity Fees $3,360 - $ -
Natural Gas $58,785 23,514 MMBtu $2.50
TOTAL ENERGY COSTS $486,229
RECOMMENDED SAVINGS* $4,452 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $1,492
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.6127 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT Savings:
$361
Cost:
$570
$361 8,397 - - - - $361
8,397
kWh
-
-
kW-months/year
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$710
Cost:
$3,438
$484 11,256 $226 42 - - $484
11,256
kWh
$226
42
kW-months/year
-
-
MMBtu
03: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$421
Cost:
$488
$287 6,669 $134 25 - - $287
6,669
kWh
$134
25
kW-months/year
-
-
MMBtu
04: 2.2425 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER Savings:
$2,960
Cost:
$4,835
- - - - $2,960 1,184 -
-
kWh
-
-
kW-months/year
$2,960
1,184
MMBtu
TOTAL RECOMMENDED Savings:
$4,452
Cost:
$9,331
$1,132 26,322 $360 67 $2,960 1,184 $1,132
26,322
kWh
$360
67
kW-months/year
$2,960
1,184
MMBtu
TOTAL IMPLEMENTED Savings:
$1,492
Cost:
$4,496
$1,132 26,322 $360 67 - - $1,132
26,322
kWh
$360
67
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas