IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2021 |
Principal Product | Bottled and Canned Soft Drinks |
NAICS | 312111 - Soft Drink Manufacturing |
SIC | 2086 - Bottled And Canned Soft Drinks |
Sales | $10,000,000-$50,000,000 |
# of Employees | 324 |
Plant Area (Sq.Ft.) | 495,245 |
Annual Production | 51,291 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | OK |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $569,810 | 14,245,259 | kWh | $0.04 |
Electricity Demand | $288,728 | 27,290 | kW-months/year | $10.58 |
Electricity Fees | $3,871 | - | $ | - |
Natural Gas | $427,175 | 168,844 | MMBtu | $2.53 |
TOTAL ENERGY COSTS | $1,644,141 | |||
RECOMMENDED SAVINGS* | $29,584 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $14,702 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $3,137 Cost: - |
$3,137 | 78,420 | - | - | - | - |
$3,137 78,420 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $8,516 Cost: $3,266 |
$8,516 | 212,887 | - | - | - | - |
$8,516 212,887 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $14,702 Cost: $14,800 |
$10,792 | 269,808 | $3,910 | 370 | - | - |
$10,792 269,808 kWh |
$3,910 370 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $3,229 Cost: $11,200 |
- | - | - | - | $3,229 | - |
- - kWh |
- - kW-months/year |
$3,229 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $29,584 Cost: $29,266 |
$22,445 | 561,115 | $3,910 | 370 | $3,229 | - | $22,445 561,115 kWh |
$3,910 370 kW-months/year |
$3,229 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $14,702 Cost: $14,800 |
$10,792 | 269,808 | $3,910 | 370 | - | - | $10,792 269,808 kWh |
$3,910 370 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees |