Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 2023 |
Principal Product | Ethyl alcohol |
NAICS | 325193 - Ethyl Alcohol Manufacturing |
SIC | 2869 - Industrial Organic Chemicals, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 19 |
Plant Area (Sq.Ft.) | 192,000 |
Annual Production | 10,900 Thousand Gallons |
Production Hrs. Annual | 8,520 |
Location (State) | KS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $475,855 | 9,517,095 | kWh | $0.05 |
Electricity Demand | $302,030 | 27,259 | kW-months/year | $11.08 |
Natural Gas | $1,784,898 | 210,801 | MMBtu | $8.47 |
TOTAL ENERGY COSTS | $2,562,783 | |||
RECOMMENDED SAVINGS* | $1,582,789 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,547,554 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | By-product Production | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | By-product Production | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $10,678 Cost: $10,052 |
$8,540 | 170,808 | $2,138 | 193 | - | - | - | - | - | - |
$8,540 170,808 kWh |
$2,138 193 kW-months/year |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $420 Cost: $900 |
$420 | 8,395 | - | - | - | - | - | - | - | - |
$420 8,395 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $29,830 Cost: $374,400 |
$29,830 | 596,602 | - | - | - | - | - | - | - | - |
$29,830 596,602 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,723 Cost: $1,260 |
$3,723 | 74,460 | - | - | - | - | - | - | - | - |
$3,723 74,460 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,087 Cost: $343 |
$832 | 16,644 | $255 | 23 | - | - | - | - | - | - |
$832 16,644 kWh |
$255 23 kW-months/year |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,010 Cost: - |
$1,010 | 20,192 | - | - | - | - | - | - | - | - |
$1,010 20,192 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $17,345 Cost: $8,534 |
$17,345 | 346,909 | - | - | - | - | - | - | - | - |
$17,345 346,909 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $12,354 Cost: $1,420 |
$12,354 | 247,080 | - | - | - | - | - | - | - | - |
$12,354 247,080 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.1131 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC |
Savings: $4,201 Cost: $632 |
- | - | - | - | $4,201 | 496 | - | - | - | - |
- - kWh |
- - kW-months/year |
$4,201 496 MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.1131 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC |
Savings: $31,034 Cost: $19,400 |
- | - | - | - | $31,034 | 3,664 | - | - | - | - |
- - kWh |
- - kW-months/year |
$31,034 3,664 MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.4146 CHANGE METHOD OF DEIONIZED WATER PRODUCTION |
Savings: $98,980 Cost: $367,077 |
$7,446 | 148,920 | $2,260 | 204 | $89,274 | 10,540 | - | - | - | - |
$7,446 148,920 kWh |
$2,260 204 kW-months/year |
$89,274 10,540 MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $150,722 Cost: $300,000 |
- | - | - | - | - | - | - | - | $150,722 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$150,722 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 3.1182 MAKE A NEW BY-PRODUCT |
Savings: $1,221,405 Cost: $1,600,000 |
- | - | - | - | - | - | $1,221,405 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,221,405 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,582,789 Cost: $2,684,018 |
$81,500 | 1,630,010 | $4,653 | 420 | $124,509 | 14,700 | $1,221,405 | - | $150,722 | - | $81,500 1,630,010 kWh |
$4,653 420 kW-months/year |
$124,509 14,700 MMBtu |
$1,221,405 - $ |
$150,722 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,547,554 Cost: $2,663,986 |
$81,500 | 1,630,010 | $4,653 | 420 | $89,274 | 10,540 | $1,221,405 | - | $150,722 | - | $81,500 1,630,010 kWh |
$4,653 420 kW-months/year |
$89,274 10,540 MMBtu |
$1,221,405 - $ |
$150,722 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | By-product Production | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | By-product Production | Increase in Production |