Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 2024
Principal Product Aircraft Parts and Auxiliary Equipment
NAICS 336413 - Other Aircraft Parts and Auxiliary Equipment Manufacturing
SIC 3728 - Aircraft Parts And Equipment, Nec
Sales $50,000,000-$100,000,000
# of Employees 80
Plant Area (Sq.Ft.) 51,512
Annual Production 5,200 Units
Production Hrs. Annual 3,744
Location (State) KS
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $69,251 865,636 kWh $0.08
Electricity Demand $35,838 3,934 kW-months/year $9.11
Natural Gas $31,616 1,622 MMBtu $19.49
TOTAL ENERGY COSTS $137,312
RECOMMENDED SAVINGS* $34,947 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$10,354
Cost:
$29,487
$7,977 99,710 $2,377 261 $7,977
99,710
kWh
$2,377
261
kW-months/year
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,075
Cost:
$1,600
$1,075 13,432 - - $1,075
13,432
kWh
-
-
kW-months/year
03: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$18,323
Cost:
$172,200
$18,323 229,040 - - $18,323
229,040
kWh
-
-
kW-months/year
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$405
Cost:
$503
$350 4,380 $55 6 $350
4,380
kWh
$55
6
kW-months/year
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$420
Cost:
-
$420 5,256 - - $420
5,256
kWh
-
-
kW-months/year
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$3,784
Cost:
$906
$3,784 47,304 - - $3,784
47,304
kWh
-
-
kW-months/year
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$586
Cost:
$430
$577 7,213 $9 1 $577
7,213
kWh
$9
1
kW-months/year
TOTAL RECOMMENDED Savings:
$34,947
Cost:
$205,126
$32,506 406,335 $2,441 268 $32,506
406,335
kWh
$2,441
268
kW-months/year
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand