Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 2024
Principal Product Fabricated metal products
NAICS 332999 - All Other Miscellaneous Fabricated Metal Product Manufacturing
SIC 3499 - Fabricated Metal Products, Nec
Sales $50,000,000-$100,000,000
# of Employees 388
Plant Area (Sq.Ft.) 813,080
Annual Production 5,100,000 Pounds
Production Hrs. Annual 2,808
Location (State) KS
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $274,369 6,859,202 kWh $0.04
Electricity Demand $389,698 18,356 kW-months/year $21.23
Electricity Fees $20,841 - $ -
Natural Gas $120,458 19,101 MMBtu $6.31
TOTAL ENERGY COSTS $834,577
RECOMMENDED SAVINGS* $248,272 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$62,690
Cost:
$117,898
$19,529 488,232 $43,161 2,033 $19,529
488,232
kWh
$43,161
2,033
kW-months/year
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,625
Cost:
$8,880
$4,625 115,632 - - $4,625
115,632
kWh
-
-
kW-months/year
03: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$28,751
Cost:
$511,000
$28,751 718,782 - - $28,751
718,782
kWh
-
-
kW-months/year
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,780
Cost:
$520
$1,780 44,500 - - $1,780
44,500
kWh
-
-
kW-months/year
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$405
Cost:
$403
$235 5,869 $170 8 $235
5,869
kWh
$170
8
kW-months/year
06: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$25,553
Cost:
$5,538
$25,553 638,820 - - $25,553
638,820
kWh
-
-
kW-months/year
07: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL Savings:
$124,468
Cost:
$710,360
$28,275 706,867 $96,193 4,531 $28,275
706,867
kWh
$96,193
4,531
kW-months/year
TOTAL RECOMMENDED Savings:
$248,272
Cost:
$1,354,599
$108,748 2,718,702 $139,524 6,572 $108,748
2,718,702
kWh
$139,524
6,572
kW-months/year
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand