Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 2025
Principal Product Casino recreation
NAICS 713210 - Casinos (except Casino Hotels)
SIC 7999 - Amusement And Recreation, Nec
Sales $10,000,000-$50,000,000
# of Employees 50
Plant Area (Sq.Ft.) 7,000
Annual Production 1 Units
Production Hrs. Annual 4,735
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $36,063 745,920 kWh $0.05
Electricity Demand $15,477 1,308 kW-months/year $11.83
Natural Gas $296 49 MMBtu $6.04
TOTAL ENERGY COSTS $54,735
RECOMMENDED SAVINGS* $7,077 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$174
Cost:
$663
$127 2,655 $47 4 $127
2,655
kWh
$47
4
kW-months/year
02: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$3,218
Cost:
$46,170
$3,218 67,036 - - $3,218
67,036
kWh
-
-
kW-months/year
03: 2.7211 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS Savings:
$2,137
Cost:
$2,175
$2,137 44,519 - - $2,137
44,519
kWh
-
-
kW-months/year
04: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$1,378
Cost:
$6,160
$1,378 28,708 - - $1,378
28,708
kWh
-
-
kW-months/year
05: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$170
Cost:
$190
$170 3,548 - - $170
3,548
kWh
-
-
kW-months/year
TOTAL RECOMMENDED Savings:
$7,077
Cost:
$55,358
$7,030 146,466 $47 4 $7,030
146,466
kWh
$47
4
kW-months/year
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand