Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Oklahoma State University
Assessment Year 2025
Principal Product Medical services
NAICS 622110 - General Medical and Surgical Hospitals
SIC 8062 - General Medical & Surgical Hospitals
Sales $5,000,000-$10,000,000
# of Employees 45
Plant Area (Sq.Ft.) 93,000
Annual Production 1 Units
Production Hrs. Annual 8,760
Location (State) OK
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $243,933 2,869,798 kWh $0.09
Natural Gas $34,264 7,987 MMBtu $4.29
TOTAL ENERGY COSTS $311,367
RECOMMENDED SAVINGS* $105,148 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$28,062
Cost:
$192,816
$28,062 330,137 - - - - $28,062
330,137
kWh
-
-
MMBtu
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$13,337
Cost:
$51,312
$13,337 156,903 - - - - $13,337
156,903
kWh
-
-
MMBtu
-
-
$
03: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$1,145
Cost:
$2,640
$1,145 13,475 - - - - $1,145
13,475
kWh
-
-
MMBtu
-
-
$
04: 2.7211 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS Savings:
$9,757
Cost:
$5,800
$9,757 114,794 - - - - $9,757
114,794
kWh
-
-
MMBtu
-
-
$
05: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$1,197
Cost:
$6,240
- - $1,197 279 - - -
-
kWh
$1,197
279
MMBtu
-
-
$
06: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE Savings:
$22,401
Cost:
$50,400
$22,401 263,543 - - - - $22,401
263,543
kWh
-
-
MMBtu
-
-
$
07: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$2,170
Cost:
$9,417
- - - - $2,170 - -
-
kWh
-
-
MMBtu
$2,170
-
$
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$17,287
Cost:
$6,120
$17,287 203,378 - - - - $17,287
203,378
kWh
-
-
MMBtu
-
-
$
09: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$315
Cost:
$1,080
$315 3,705 - - - - $315
3,705
kWh
-
-
MMBtu
-
-
$
10: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$959
Cost:
$800
$959 11,283 - - - - $959
11,283
kWh
-
-
MMBtu
-
-
$
11: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS Savings:
$1,384
Cost:
$16,085
$839 9,876 $545 127 - - $839
9,876
kWh
$545
127
MMBtu
-
-
$
12: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$7,134
Cost:
$13,000
- - $7,134 1,663 - - -
-
kWh
$7,134
1,663
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$105,148
Cost:
$355,710
$94,102 1,107,094 $8,876 2,069 $2,170 - $94,102
1,107,094
kWh
$8,876
2,069
MMBtu
$2,170
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $